Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model with Manual Air Conditioning System) › from 2020.11
RM37A0E _58 Vehicle Interior _086896 HEATING / AIR CONDITIONING _0453069 AIR CONDITIONING SYSTEM(for Gasoline Model with Manual Air Conditioning System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Manual Air Conditioning System)  Blower Motor Circuit  


DESCRIPTION

The blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly.

If the airflow volume is low or the blower speed cannot be changed, the following factors may be the cause.

Symptom Factor
Airflow volume cannot be changed
·

Air conditioning amplifier assembly malfunction

·

Blower motor with fan sub-assembly malfunction

·

Harness or connector



WIRING DIAGRAM

E432291E02
5.125,0.896 5.583,1.094 0.458,0.198 10 false BLW 4.771,0.813 5.229,1.01 0.458,0.198 10 false 21 5.135,1.406 5.594,1.604 0.458,0.198 10 false GND 4.76,1.26 5.219,1.458 0.458,0.198 10 false 17 6.135,1 6.594,1.198 0.458,0.198 10 false IC 2.625,0.74 3.083,0.938 0.458,0.198 10 false HTR 3.667,0.594 4.76,0.844 1.094,0.25 10 false from ALT Fuse 1.865,0.615 2.323,0.813 0.458,0.198 10 false +B 2.135,0.521 2.594,0.719 0.458,0.198 10 false 3 1.896,1.01 2.354,1.208 0.458,0.198 10 false SI 2.135,0.896 2.594,1.094 0.458,0.198 10 false 2 2.125,1.281 2.583,1.479 0.458,0.198 10 false 1 1.74,1.396 2.198,1.594 0.458,0.198 10 false GND 0.292,2 0.75,2.198 0.458,0.198 10 false A25 0.281,2.167 2.854,2.417 2.573,0.25 10 false Blower Motor with Fan Sub-assembly 4.729,1.469 5.188,1.667 0.458,0.198 10 false H62 4.74,2.01 7.115,2.229 2.375,0.219 10 false Air Conditioning Amplifier Assembly 4.719,1.01 5.177,1.208 0.458,0.198 10 false H62

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

1.PERFORM ACTIVE TEST USING GTS (BLOWER MOTOR)
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Body Electrical > Air Conditioner > Active Test
Tester Display
Blower Motor
50004 121 2

Result:
Result Proceed to
Blower motor with fan sub-assembly does not operate A
Blower motor with fan sub-assembly operates but does not change speed B



A

2.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - BATTERY AND BODY GROUND)

B

5.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
2.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - BATTERY AND BODY GROUND)
a.
E432377C01
1.479,0.188 1.979,0.438 0.5,0.25 2.083,1.167 2.333,0.833 2.333,0.833 2.583,0.833 true 1.333,1.167 1.083,0.833 1.083,0.833 0.833,0.833 true 0.083,0.063 0.396,0.26 0.313,0.198 10 false *a 0.615,0.75 0.927,0.948 0.313,0.198 10 false +B 2.646,0.75 3.031,0.958 0.385,0.208 10 false GND 1.604,0.229 1.917,0.427 0.313,0.198 10 false A25
*a Rear view of wire harness connector
(to Blower Motor with Fan Sub-assembly)


Disconnect the A25 blower motor with fan sub-assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A25-1 (GND) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A25-3 (+B) - Body ground Ignition switch off 11 to 14 V



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY)
a.

Disconnect the H62 air conditioning amplifier assembly connector.


b.

Disconnect the A25 blower motor with fan sub-assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H62-21 (BLW) - A25-2 (SI) Always Below 1 Ω
H62-21 (BLW) or A25-2 (SI) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

4.CHECK BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK BLOWER MOTOR WITH FAN SUB-ASSEMBLY
a.

Connect the A25 blower motor with fan sub-assembly connector.


b.
E432378C01
1.448,0.135 1.948,0.385 0.5,0.25 1.323,1.917 1.521,1.365 true 1.573,0.177 2.031,0.375 0.458,0.198 10 false H62 1.167,1.938 1.552,2.104 0.385,0.167 10 false BLW 0.469,0.115 0.927,0.313 0.458,0.198 10 false *a
*a Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)


Disconnect the H62 air conditioning amplifier assembly connector.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
H62-21 (BLW) - Body ground Always 4.75 to 5.25 V



Result:
Proceed to
OK
NG



OK

5.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

5.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
a.

Connect the H62 air conditioning amplifier assembly connector.


b.

Using an oscilloscope, check the waveform.

E432379C01
5.146,0.135 5.563,0.396 0.417,0.26 5.854,1.969 5.521,1.208 true 4.969,1.969 4.802,1.063 true 5.24,0.188 5.698,0.385 0.458,0.198 10 false H62 4.635,0.156 4.948,0.354 0.313,0.198 10 false *a 4.677,2.969 5.135,3.167 0.458,0.198 10 false GND 5.75,2 6.208,2.198 0.458,0.198 10 false BLW 4.844,2.01 5.302,2.208 0.458,0.198 10 false GND
*a Component with harness connected
(Air Conditioning Amplifier Assembly)
- -


Item Content
Terminal No. H62-21 (BLW) - H62-17 (GND)
Tool Setting 2 V/DIV., 1 ms./DIV.
Condition
·

Ignition switch ON

·

Blower speed: LO



OK:

Waveform is similar to that shown in the illustration.


HINT:

The waveform varies with the blower speed.



Result:
Proceed to
OK
NG



OK

REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY