HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Manual Air Conditioning System)  A/C Switch Indicator does not Turn On  


DESCRIPTION

If none of the switch indicators on the air conditioning control assembly illuminate, the following factors may be the cause.

Malfunction Status Factor
A/C switch indicator does not illuminate
·

Air conditioning amplifier assembly malfunction

·

Air conditioning control assembly malfunction

·

A/C switch malfunction

·

A/C switch indicator malfunction (including when indicator turned off without switch operation)

·

Servo motor initialization (incomplete)

·

Mechanical locking of damper and damper link

·

Refrigerant pressure is extremely low

·

Low detected ambient temperature (including thermistor assembly malfunction)



PROCEDURE

1.CHECK MALFUNCTION STATUS
a.

Check the malfunction status of switch indicators on the air conditioning control assembly.


Result:
Result Proceed to
A/C switch indicators are not always illuminated A
A/C switch indicators are not illuminated only immediately after starting the engine B



A

2.READ VALUE USING GTS (AMBIENT TEMP SENSOR)

B

2.READ VALUE USING GTS (AMBIENT TEMP SENSOR)
a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Ambient Temp Sensor Ambient temp. sensor (thermistor assembly) Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed Ambient temp. sensor (thermistor assembly) circuit malfunction
·

When open circuit: -23.30°C (-9.94°F)

·

When short circuit: 65.95°C (150.71°F)


Body Electrical > Air Conditioner > Data List
Tester Display
Ambient Temp Sensor
50003 121 2
OK:

The display is as specified in the normal condition column (0°C (32°F) or higher).



Result:
Proceed to
OK
NG



OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

NG