The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors.
The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly.
Each servo motor sends damper position information to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1497 | Communication Malfunction (Bus Ic) | Error or open in communication line between air conditioning amplifier assembly and any of the following servo motors.
·
No. 1 air conditioning radiator damper servo sub-assembly ·
No. 2 air conditioning radiator damper servo sub-assembly*1 |
·
Air conditioning harness assembly ·
Air conditioning amplifier assembly |
Memorized
(10 sec. or more)*2 |
*1: for LHD
*2: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Air Outlet Servo Pulse (D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) pulse for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (front side mode) pulse |
Min.: 128
Max.: 383 |
for LHD:
Operates between 164 to 278 pulses for RHD:
Operates between 234 to 348 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 220 to 256 pulses |
| Air Outlet Servo Pulse (P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) pulse (for LHD) | Min.: 128
Max.: 383 |
Operates between 234 to 348 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
| Tester Display |
|---|
| Air Outlet Servo Pulse (D) |
| Tester Display |
|---|
| Air Inlet Damper Targ Pulse |
| Tester Display |
|---|
| Air Outlet Servo Pulse (P) |
Damper servo motor is operated.
| Result | Proceed to |
|---|---|
| All damper servo motors are not operated | A |
| Any damper servo motor is not operated | B |
| All damper servo motors are operated | C |
A
B
C
Disconnect the z19 air conditioning amplifier assembly connector.
| *a | Component without harness connected
(Air Conditioning Amplifier Assembly) |
- | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z19-2 (BUS G) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z19-4 (B BUS) - z19-2 (BUS G) | Ignition switch off | 11 to 14 V |
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Tester Connection | z19-3 (BUS) - z19-2 (BUS G) |
| Tool Setting | 2 V/DIV., 20 μs/DIV. |
| Condition | Ignition switch ON |
The waveform displays properly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG