Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for HV Model) › 2020.11–2021.10
RM37A0E _58 Vehicle Interior _086896 HEATING / AIR CONDITIONING _0420832 AIR CONDITIONING SYSTEM(for HV Model) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model)  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Air Conditioner

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Room temp. sensor (cooler thermistor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed Room temp. sensor (cooler thermistor) circuit malfunction
·

When open circuit: -6.50°C (20.30°F)

·

When short circuit: 57.25°C (135.05°F)


Ambient Temp Sensor Ambient temp. sensor (thermistor assembly) Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed Ambient temp. sensor (thermistor assembly) circuit malfunction
·

When open circuit: -23.30°C (-9.94°F)

·

When short circuit: 65.95°C (150.71°F)


Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
Adjust ambient temperature displayed Air conditioning amplifier assembly circuit malfunction
Evaporator Fin Thermistor Evaporator temp. sensor (No. 1 cooler thermistor) Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed Evaporator temp. sensor (No. 1 cooler thermistor) circuit malfunction
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed Evaporator temp. sensor (No. 1 cooler thermistor) circuit malfunction
·

When open circuit: -327.68°C (-557.82°F)

·

When short circuit: 327.67°C (621.81°F)


Solar Sensor (D Side) Driver side automatic light control sensor Min.: 0
Max.: 255
Driver side automatic light control sensor value increases as brightness increases Driver side automatic light control sensor circuit malfunction
·

When open circuit: 0

·

When short circuit: 255


Solar Sensor (P Side) Front passenger side automatic light control sensor Min.: 0
Max.: 255
Front passenger side automatic light control sensor value increases as brightness increases Front passenger side automatic light control sensor circuit malfunction
·

When open circuit: 0

·

When short circuit: 255


Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
·

SFI system malfunction

·

CAN communication system malfunction


Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower motor with fan sub-assembly circuit malfunction
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -456.68 kPaG (gauge)
Max.: 3294.37 kPaG (gauge)
Actual refrigerant pressure displayed
·

Refrigerant line (gas leak etc.)

·

Air conditioner pressure sensor circuit malfunction


Room Temp Sensor (Rear) No. 2 room temp. sensor (cooler thermistor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin (rear) temperature displayed No. 2 room temp. sensor (cooler thermistor) circuit malfunction
·

When open circuit: -6.50°C (20.30°F)

·

When short circuit: 57.25°C (135.05°F)


Evap Temp Sensor (Rear) Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator (rear) temperature displayed Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) circuit malfunction
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Blower Motor Level (Rear) Rear blower motor control Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor (rear) speed increases Rear blower motor control circuit malfunction
Air Outlet Servo Pulse (R) Rear mode damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

FACE: 276 (pulse)

·

B/L: 228 (pulse)

·

FOOT: 200 (pulse)


Rear mode damper servo sub-assembly circuit malfunction
Air Outlet Servo Actual Pls(R) Rear mode damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

FACE: 276 (pulse)

·

B/L: 228 (pulse)

·

FOOT: 200 (pulse)


Rear mode damper servo sub-assembly circuit malfunction
Air Mix Servo Targ Pulse(R) Rear air mix damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

MAX COLD: 258 (pulse)

·

MAX HOT: 213 (pulse)


Rear air mix damper servo sub-assembly circuit malfunction
Air Mix Servo Actual Pulse(R) Rear air mix damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

MAX COLD: 258 (pulse)

·

MAX HOT: 213 (pulse)


Rear air mix damper servo sub-assembly circuit malfunction
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


for RHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction
Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


for RHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction
Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


for RHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction
Air Mix Servo Actual Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


for RHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction
Air Outlet Servo Pulse (D)
for LHD:
·

No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) target pulse


for RHD:
·

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) target pulse


Min.: 128
Max.: 383
for LHD:
·

S-FLOW: 278 (pulse)

·

FACE: 256 (pulse)

·

B/L: 245 (pulse)

·

FOOT-A: 224 (pulse)

·

FOOT-R(F): 215 (pulse)

·

FOOT-D: 207 (pulse)

·

F/D-R: 192 (pulse)

·

D/F: 173 (pulse)

·

DEF: 164 (pulse)


for RHD:
·

S-FLOW: 234 (pulse)

·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-A: 288 (pulse)

·

FOOT-R(F): 297 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

D/F: 339 (pulse)

·

DEF: 348 (pulse)


for LHD:
·

No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction


for RHD:
·

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction


Air Outlet Servo Actu Pulse(D)
for LHD:
·

No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) actual pulse


for RHD:
·

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) actual pulse


Min.: 128
Max.: 383
for LHD:
·

S-FLOW: 278 (pulse)

·

FACE: 256 (pulse)

·

B/L: 245 (pulse)

·

FOOT-A: 224 (pulse)

·

FOOT-R(F): 215 (pulse)

·

FOOT-D: 207 (pulse)

·

F/D-R: 192 (pulse)

·

D/F: 173 (pulse)

·

DEF: 164 (pulse)


for RHD:
·

S-FLOW: 234 (pulse)

·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-A: 288 (pulse)

·

FOOT-R(F): 297 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

D/F: 339 (pulse)

·

DEF: 348 (pulse)


for LHD:
·

No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction


for RHD:
·

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction


Air Outlet Servo Targ Pulse(P)
for LHD:
·

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) target pulse


for RHD:
·

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side mode) target pulse


Min.: 128
Max.: 383
for LHD:
·

S-FLOW: 234 (pulse)

·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-A: 288 (pulse)

·

FOOT-R(F): 297 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

D/F: 339 (pulse)

·

DEF: 348 (pulse)


for RHD:
·

S-FLOW: 278 (pulse)

·

FACE: 256 (pulse)

·

B/L: 245 (pulse)

·

FOOT-A: 224 (pulse)

·

FOOT-R(F): 215 (pulse)

·

FOOT-D: 207 (pulse)

·

F/D-R: 192 (pulse)

·

D/F: 173 (pulse)

·

DEF: 164 (pulse)


for LHD:
·

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction


for RHD:
·

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction


Air Outlet Servo Actu Pulse(P)
for LHD:
·

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) actual pulse


for RHD:
·

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side mode) actual pulse


Min.: 128
Max.: 383
for LHD:
·

S-FLOW: 234 (pulse)

·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-A: 288 (pulse)

·

FOOT-R(F): 297 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

D/F: 339 (pulse)

·

DEF: 348 (pulse)


for RHD:
·

S-FLOW: 278 (pulse)

·

FACE: 256 (pulse)

·

B/L: 245 (pulse)

·

FOOT-A: 224 (pulse)

·

FOOT-R(F): 215 (pulse)

·

FOOT-D: 207 (pulse)

·

F/D-R: 192 (pulse)

·

D/F: 173 (pulse)

·

DEF: 164 (pulse)


for LHD:
·

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction


for RHD:
·

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction


Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Electric Heater Count - - - Cannot be used
Electric Heater Active Level - - - Cannot be used
Compressor Speed Compressor speed Min.: 0 rpm
Max.: 65535 rpm
Actual compressor speed displayed -
Compressor Target Speed Compressor target speed Min.: 0 rpm
Max.: 65535 rpm
Compressor target speed displayed -
Shift Set Temperature Shift set temperature 2C decr / 1C decr / Normal / 1C incr / 2C incr Customized value displayed -
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
Compressor Mode Compressor mode Auto or Manual Customized value displayed -
Noise and Vibration Reduction Function to change the speed of the compressor when set to ON OFF or ON Customized value displayed -
ECO MODE Cancel Function to cancel ECO mode when set to ON OFF or ON Customized value displayed -
ECO Switch - - - Cannot be used
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Fan speed increment control Fan speed increment control Slow / Normal / Fast Customized value displayed -
Foot/DEF Auto Mode Foot/defroster auto mode ON or OFF Customized value displayed -
Foot/DEF Auto Blow Up Foot/defroster auto blower speed increase ON or OFF Customized value displayed -
Ambient Temperature Shift Ambient temperature shift 3C decr / 2C decr / 1C decr / Normal / 1C incr / 2C incr / 3C incr Customized value displayed -
Compressor Drive Check Compressor drive check OK or NG OK: Compressor drives
NG: Compressor does not drive
-
Glass Temperature Glass temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual glass temperature displayed -
Glass Surroundings Temperature Glass surroundings temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual glass surroundings temperature displayed -
Glass Humidity Glass humidity Min.: 0%
Max.: 100%
Actual glass humidity displayed -
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
FR Seat Heater Temperature - - - Although this item is displayed on the GTS, it is not applicable to the air conditioning system.
FL Seat Heater Temperature - - - Although this item is displayed on the GTS, it is not applicable to the air conditioning system.
RR Seat Heater Temperature - - - Although this item is displayed on the GTS, it is not applicable to the air conditioning system.
RL Seat Heater Temperature - - - Although this item is displayed on the GTS, it is not applicable to the air conditioning system.
Set Temperature (D Side) Driver side set temperature Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed -
Set Temperature (P Side) Front passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Front passenger side set temperature displayed -
Set Temperature (Rear) Rear passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Rear passenger side set temperature displayed -
Operation Limitation Control History Count (Level1) History of auxiliary battery voltage drop in the past Min.: 0
Max.: 255
Number of times auxiliary battery voltage dropped in the past displayed
·

Counted when voltage drops below the specified level due to over discharge while driving.

·

*1


Operation Limitation Control History Count (Level2) History of auxiliary battery voltage drop in the past Min.: 0
Max.: 255
Number of times auxiliary battery voltage dropped in the past displayed
·

Counted when voltage drops below the specified level due to over discharge while driving.

·

*1


Outside Air Mode Auto Switch Function Outside air mode auto switch function ON or OFF Customized value displayed -
S-FLOW Control Auto Function S-FLOW control auto function ON or OFF Customized value displayed -
Seat Blast Mode Setting - - - Although this item is displayed on the GTS, it is not applicable to the air conditioning system.
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -
Refrigerant High Pressure History Refrigerant high pressure history Min.: 0
Max.: 255
Number of times refrigerant high pressure history stored displayed *2

*1: Refer to the following procedure to clear the A/C operation limitation history.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>UTILITY

*2: Refer to the following procedure to clear the refrigerant high pressure history.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>UTILITY


b.

Engine

Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F)
Max.: 140°C (284°F)
75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

·

If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

·

Check if the engine overheats if the value indicated is higher than 135°C (275°F).




c.

Rain and/or Humidity Sensor

Body Electrical > Rain and/or Humidity Sensor > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Glass Humidity Windshield glass humidity Min.: 0.0%
Max.: 100.0%
Actual windshield glass humidity is displayed -
Glass Temperature Windshield glass temperature Min.: -30.0°C (-22°F)
Max.: 70.0°C (158°F)
Actual windshield glass temperature is displayed -
Glass Surroundings Temperature Temperature around windshield glass Min.: -30.0°C (-22°F)
Max.: 70.0°C (158°F)
Actual temperature around windshield glass is displayed -
Number of Trouble Code Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -


ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Air Conditioner

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Compressor Target Speed Compressor with motor assembly Min.: 0
Max.: 7500
-
Defogger Relay (Rear) Rear window defogger OFF or ON -
Deicer Relay (Front) Windshield deicer OFF or ON -
Heater Active Level - - -
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Air Outlet Servo Pulse (D)
for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) pulse


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) pulse


Min.: 128
Max.: 383
for LHD:

Operates between 164 to 278 pulses


for RHD:

Operates between 234 to 348 pulses


Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 220 to 256 pulses
Rear Blower Motor Rear blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Rear Air Mix Servo Targ Pulse Rear air mix damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 213 to 258 pulses
Air Outlet Servo Pulse (P)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) pulse


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side mode) pulse


Min.: 128
Max.: 383
for LHD:

Operates between 234 to 348 pulses


for RHD:

Operates between 164 to 278 pulses


A/O Servo Pulse(Rr D) Rear mode damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 200 to 276 pulses
HWD Relay - - Although this test is displayed on the GTS, it is not applicable to the air conditioning system.
Front Right Seat Heater - - Although this test is displayed on the GTS, it is not applicable to the air conditioning system.
Front Left Seat Heater - - Although this test is displayed on the GTS, it is not applicable to the air conditioning system.
Rear Right Seat Heater - - Although this test is displayed on the GTS, it is not applicable to the air conditioning system.
Rear Left Seat Heater - - Although this test is displayed on the GTS, it is not applicable to the air conditioning system.
Front Right Seat Blower - - Although this test is displayed on the GTS, it is not applicable to the air conditioning system.
Front Left Seat Blower - - Although this test is displayed on the GTS, it is not applicable to the air conditioning system.

b.

Engine

Powertrain > Engine > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Control the Engine Cooling Fan Duty Ratio Control the cooling fan 0 to 100% Perform this test when vehicle is stopped.