Home › General › SPECIFICATIONS › A25A-FXS, A25B-FXS EMISSION CONTROL › from 2020.11
RM37A0E _V1 General _086915 SPECIFICATIONS _0415880 A25A-FXS EMISSION CONTROL F

SPECIFICATIONS  A25A-FXS EMISSION CONTROL  SERVICE DATA  


EGR VALVE ASSEMBLY
Tester Connection Condition Specified Condition
1 (EGA+) - 2 (EGA-) 20°C (68°F) 3.1 to 3.7 Ω
3 (EGB-) - 4 (EGB+)

PURGE VALVE (PURGE VSV)
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω

DIFFERENTIAL PRESSURE SENSOR
GTS Display Condition Specified Condition
GPF Differential Pressure SensorBank 1 Power switch on (IG) When applying 20 kPa (2.9 psi):20 kPa (2.9 psi)
When applying 40 kPa (5.8 psi):40 kPa (5.8 psi)