When the shift lever is in M and moved toward "-" or "+", it is possible to select different shift ranges (M1 to M8).
Moving the shift lever toward "+" increases the shift range by one, and moving the shift lever toward "-" decreases the shift range by one.
Inspect the fuses for circuits related to this system before performing the following procedure.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Shift SW Status (S Range) | Sport (M) mode select switch status | ON or OFF | ·
ON: Shift lever in M, "+" or "-" ·
OFF: Shift lever not in M, "+" or "-" |
- |
| Tester Display |
|---|
| Shift SW Status (S Range) |
| Result | Proceed to |
|---|---|
| Data List value is normal | A |
| Data List value is not normal | B |
A
B
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Sport Shift Up SW | Sport shift up switch status | ON or OFF | ·
ON: Shift lever held in "+" ·
OFF: Shift lever not held in "+" |
- |
| Sport Shift Down SW | Sport shift down switch status | ON or OFF | ·
ON: Shift lever held in "-" ·
OFF: Shift lever not held in "-" |
- |
| Tester Display |
|---|
| Sport Shift Up SW |
| Sport Shift Down SW |
| Result | Proceed to |
|---|---|
| Data List values are normal | A |
| Data List values are not normal | B |
A
B
Disconnect the H29 transmission control switch connector.
| *a | Component without harness connected
(Transmission Control Switch (Shift Lock Control Unit Assembly)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (SFTU) - 2 (E) | Shift lever held in "+" (Up shift) | Below 1 Ω |
| Shift lever not held in "+" (Up shift) | 10 kΩ or higher | |
| 1 (SFTD) - 2 (E) | Shift lever held in "-" (Down shift) | Below 1 Ω |
| Shift lever not held in "-" (Down shift) | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H29 transmission control switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H29-2 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the H29 transmission control switch connector.
Disconnect the A28 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A28-38 (SFTU) - Body ground | Shift lever held in "+" (Up shift) | Below 1 Ω |
| A28-38 (SFTU) - Body ground | Shift lever not held in "+" (Up shift) | 10 kΩ or higher |
| A28-37 (SFTD) - Body ground | Shift lever held in "-" (Down shift) | Below 1 Ω |
| A28-37 (SFTD) - Body ground | Shift lever not held in "-" (Down shift) | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Transmission Control Switch (Shift Lock Control Unit Assembly)) |
Disconnect the H29 transmission control switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (IG) - 5 (S) | Shift lever in M, "+" or "-" | Below 1 Ω |
| Shift lever not in M, "+" or "-" | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H29 transmission control switch connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H29-4 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H29 transmission control switch connector.
Disconnect the A28 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H29-5 (S) - A28-17 (S) | Always | Below 1 Ω |
| H29-5 (S) or A28-17 (S) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG