DTC P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0748 | TCM checks for an open or short in shift solenoid valve SL1 circuit while driving and shifting between 4th and 5th gear (1 trip detection logic) Output signal duty equal to 100%
|
|

| TCM gear shift command | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve SL1 | OFF | OFF | OFF | OFF | ON |
| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1) |
![]() |
Disconnect the E1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 12 (SL1+) - 4 (SL1-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 12 (SL1+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| 4 (SL1-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
![]() |
Disconnect the T19 TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| T19-9 (SL1+) - T19-8 (SL1-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| T19-9 (SL1+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| T19-8 (SL1-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SL1 |
![]() |
Remove the shift solenoid valve SL1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
|
| ||||
| OK | ||
| ||