DTC P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0778 | ECM checks for an open or short in shift solenoid valve SL2 circuit while driving and shifting between 4th and 5th gear (1 trip detection logic) Output signal duty equal to 100%
|
|

| ECM gear shift command | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve SL2 | ON | ON | ON | ON | OFF |
| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2) |
![]() |
Disconnect the E1 wire connector.
Measure the resistance of the wire connector.
| Tester Connection | Condition | Specified Condition |
| 11 (SL2+) - 3 (SL2-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 11 (SL2+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| 3 (SL2-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the E16 ECM connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| E16-17 (SL2+) - E16-16 (SL2-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| E16-17 (SL2+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| E16-16 (SL2-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SL2 |
![]() |
Remove the shift solenoid valve SL2.
Measure the resistance of the solenoid valve.
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
Check the operating noise of the solenoid valve.
![]() |
| Item | Content |
| Tester Connection | E16-17 (SL2+) - E16-16 (SL2-) |
| Tool Setting | 5 V/DIV., 1 msec./DIV. |
| Condition | Engine is idling |
|
| ||||
| OK | ||
| ||