DTC P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR) |
DTC P0986 Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0985 | TCM detects short in solenoid valve SR circuit 2 times when solenoid valve SR is operated (1 trip detection logic) |
|
| P0986 | TCM detects open in solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1 trip detection logic) |
|

| TCM gear shift command | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve SR | OFF | OFF | OFF | OFF | ON |
| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR) |
![]() |
Disconnect the E1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 7 - Body ground | 20°C (68°F) | 11 to 15 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
![]() |
Disconnect the T19 TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| T19-16 (SR) - Body ground | 20°C (68°F) | 11 to 15 Ω |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SR |
![]() |
Remove the shift solenoid valve SR.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve SR connector terminal - Shift solenoid valve SR body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
|
| ||||
| OK | ||
| ||