C1241/41
| When one of the following conditions is met:
- At a vehicle speed of 3 km/h (2 mph) or more, the IG1 terminal voltage is less than 9.5 V for 10 seconds or more.
- The solenoid relay remains ON, the IG1 terminal voltage is less than 9.5 V, and the relay contact is open for 0.2 seconds or more.
- With the IG1 terminal voltage 9.5 V or less, the vehicle speed sensor power supply voltage decreases and stays at or below a certain value for 60 seconds or more.
- While the motor fail-safe relay is ON after the motor relay turns ON, the IG1 terminal voltage is 9.5 V or less and the actuator pump drive motor is OFF for 0.2 seconds or more.
- The IG1 terminal voltage is more than 17.4 V for 0.8 seconds or more.
| - ECU-IG&GAUGE fuse
- Battery
- Charging system
- IG power source circuit