DTC P0100/31 Mass or Volume Air Flow Circuit |
DTC P0102/31 Mass or Volume Air Flow Circuit Low Input |
DTC P0103/31 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0100/31 | When MAF meter circuit has open or short for more than 3 seconds under 2,000 rpm engine speed (1 trip detection logic) |
|
| P0102/31 | When MAF meter circuit has open for more than 3 seconds under 2,000 rpm engine speed (1 trip detection logic) |
|
| P0103/31 | When MAF meter circuit has short for more than 3 seconds under 2,000 rpm engine speed (1 trip detection logic) |
|
| Air Flow Rate (gm/s) | Malfunction |
| Approximately 0.0 |
|
| 167.5 or more | Open in EVG circuit |

| 1.READ DATA LIST (MASS AIR FLOW RATE) |
Connect the intelligent tester to the DLC3.
Start the engine and turn the intelligent tester ON.
Enter the following menus: Powertrain / Engine / Data List / MAF.
Read the values.
| Air Flow Rate (gm/s) | Proceed to |
| 0.0 | A |
| 167.5 or more | B |
| Between 1 and 167.4* | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK MASS AIR FLOW METER (POWER SOURCE) |
![]() |
Disconnect the A4 MAF meter connector.
Turn the ignition switch ON.
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| A4-1 (+B) - Body ground | 9 to 14 V |
|
| ||||
| OK | |
| 3.CHECK ECM (VG VOLTAGE) |
![]() |
Start the engine.
Measure the voltage of the ECM connector.
| Tester Connection | Condition | Specified Condition |
| E7-24 (VG) - E7-32 (EVG) | Engine idling | 0.5 to 3.4 V |
|
| ||||
| NG | |
| 4.CHECK WIRE HARNESS (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the A4 MAF meter connector.
Disconnect the E7 ECM connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A4-3 (VG) - E7-24 (VG) | Below 1 Ω |
| A4-2 (E2G) - E7-32 (EVG) | Below 1 Ω |
| A4-3 (VG) or E7-24 (VG) - Body ground | 10 kΩ or higher |
| A4-2 (E2G) or E7-32 (EVG) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK WIRE HARNESS (MASS AIR FLOW METER - INTEGRATION RELAY (MAIN RELAY)) |
![]() |
Disconnect the A4 MAF meter connector.
Remove the integration relay from the engine room junction block (Click here).
Disconnect the 1J integration relay connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A4-1 (+B) - 1J-5 | Below 1 Ω |
| A4-1 (+B) or 1J-5 - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 6.CHECK ECM (SENSOR GROUND) |
![]() |
Measure the resistance of the ECM connector.
| Tester Connection | Specified Condition |
| E7-32 (EVG) - Body ground | Below 1 Ω |
|
| ||||
| OK | |
| 7.CHECK WIRE HARNESS (MASS AIR FLOW METER- ECM) |
![]() |
Disconnect the A4 MAF meter connector.
Disconnect the E7 ECM connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A4-3 (VG) - E7-24 (VG) | Below 1 Ω |
| A4-2 (E2G) - E7-32 (EVG) | Below 1 Ω |
| A4-3 (VG) or E7-24 (VG) - Body ground | 10 kΩ or higher |
| A4-2 (E2G) or E7-32 (EVG) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 1.CHECK ECM (VG VOLTAGE) |
![]() |
Start the engine.
Measure the voltage of the ECM connector.
| Tester Connection | Condition | Specified Condition |
| E7-24 (VG) - E7-32 (EVG) | Engine idling | 0.5 to 3.4 V |
|
| ||||
| NG | |
| 2.CHECK MASS AIR FLOW METER (POWER SOURCE) |
![]() |
Disconnect the A4 MAF meter connector.
Turn the ignition switch ON.
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| A4-1 (+B) - Body ground | 9 to 14 V |
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the A4 MAF meter connector.
Disconnect the E7 ECM connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A4-3 (VG) - E7-24 (VG) | Below 1 Ω |
| A4-2 (E2G) - E7-32 (EVG) | Below 1 Ω |
| A4-3 (VG) or E7-24 (VG) - Body ground | 10 kΩ or higher |
| A4-2 (E2G) or E7-32 (EVG) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 4.CHECK WIRE HARNESS (MASS AIR FLOW METER - INTEGRATION RELAY (MAIN RELAY)) |
![]() |
Disconnect the A4 MAF meter connector.
Remove the integration relay from the engine room junction block (Click here).
Disconnect the 1J integration relay connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A4-1 (+B) - 1J-5 | Below 1 Ω |
| A4-1 (+B) or 1J-5 - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||