DTC P0135/21 Oxygen Sensor Heater Circuit (Bank 1 Sensor 1) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0135/21 | Open or short in heater circuit of oxygen sensor for 0.5 seconds or more |
|
| 1.INSPECT HEATED OXYGEN SENSOR |
![]() |
Disconnect the H6 sensor connector.
Measure the resistance of the sensor.
| Tester Connection | Condition | Specified Condition |
| 1 (HT1A) - 2 (+B) | 20°C (68°F) | 5 to 10 Ω |
| 1 (HT1A) - 4 (E2) | - | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (+B VOLTAGE) |
![]() |
Disconnect the H6 heated oxygen sensor connector.
Turn the ignition switch ON.
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| H6-2 (+B) - Body ground | 9 to 14 V |
|
| ||||
| NG | |
| 3.INSPECT INTEGRATION NO.1 RELAY (MAIN RELAY) |
![]() |
Remove the integration relay from the engine room junction block .
Measure the voltage of the MAIN relay.
| Tester Connection | Condition | Specified Condition |
| 1J-5 - Body ground | Ignition switch ON | 10 to 14 V |
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (HEATED OXYGEN SENSOR - ECM AND INTEGRATION RELAY (MAIN)) |
![]() |
Disconnect the H6 sensor connector.
Disconnect the E12 ECM connector.
Disconnect the 1J connector from the engine room junction block .
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| H6-1 - E12-1 (HT1A) | Below 1 Ω |
| H6-2 (+B) - 1J-5 | Below 1 Ω |
| H6-1 or E12-1 (HT1A) - Body ground | 10 kΩ or higher |
| H6-2 (+B) or 1J-5 - Body ground | 10 kΩ or higher |
|
| ||||
| OK | |
| 5.CHECK IF DTC OUTPUT RECURS |
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read the DTCs.
| Display (DTC output) | Proceed to |
| No output | A |
| Heated oxygen sensor circuit DTCs | B |
|
| ||||
| A | ||
| ||