GENERATOR > DISASSEMBLY |
| 1. INSPECT GENERATOR WITH VACUUM PUMP ASSEMBLY |
Mount the generator in a vise.
Insert a screwdriver to hold the generator rotor.
Hold the bolt and nut to the pulley.
![]() |
Set a dial indicator as shown in the illustration.
Turn the pulley and measure the backlash between the generator rotor and vacuum pump shaft.
| 2. REMOVE VACUUM PUMP ASSEMBLY |
![]() |
Place the matchmarks as shown in the illustration.
Remove the 4 bolts and vacuum pump.
| 3. REMOVE GENERATOR REAR END COVER |
![]() |
Remove the nut and terminal insulator.
Remove the bolt, 3 nuts, plate terminal and rear end cover.
| 4. REMOVE BRUSH HOLDER AND REGULATOR |
Remove the brush holder cover.
![]() |
Remove the 2 screws and brush holder.
Remove the seal plate.
Remove the 3 screws and regulator.
| 5. REMOVE GENERATOR HOLDER WITH RECTIFIER |
![]() |
Remove the 4 screws and generator holder with rectifier.
Remove the 4 rubber insulators.
| 6. REMOVE GENERATOR RECTIFIER END FRAME |
![]() |
Remove the 4 nuts and cord clamp.
![]() |
Using SST, remove the rectifier end frame.
Remove the washer from the rotor.
| 7. REMOVE GENERATOR ROTOR ASSEMBLY |
![]() |
Using SST and a press, press out the rotor.