Home › ENGINE ยท 5L-E › CHARGING › GENERATOR

GENERATOR > INSTALLATION

for Preparation Click here



1. INSTALL GENERATOR ASSEMBLY


    A122287
  1. Install the generator with the bolt.

    Torque:
    75 N*m{ 765 kgf*cm , 55 ft.*lbf }

  1. Connect the vacuum oil outlet hose.



    A118425
  1. Install 2 new gaskets and the vacuum pump hose with the union bolt.

    Torque:
    14 N*m{ 143 kgf*cm , 10 ft.*lbf }

  1. Install the vacuum pump oil inlet hose with 2 new gaskets and the union bolt.

    Torque:
    14 N*m{ 143 kgf*cm , 10 ft.*lbf }

  1. Attach the vacuum pump oil inlet hose to the cord clip.



    A118424
  1. Install the generator wire with the nut.

    Torque:
    9.8 N*m{ 100 kgf*cm , 7 ft.*lbf }

  1. Attach the terminal cap.

  1. Connect the generator connector.



2. INSTALL COMPRESSOR MOUNTING BRACKET (w/ Air Conditioning System)


    A121135E02
  1. Temporarily install the compressor mounting bracket with the 4 bolts.

  1. Using several steps, uniformly install and tighten the 4 bolts in the sequence shown in the illustration.

    Torque:
    85 N*m{ 865 kgf*cm , 63 ft.*lbf }



    A112016E01
  1. Temporarily tighten the bolt and spacer.

    Torque:
    18 N*m{ 184 kgf*cm , 13 ft.*lbf }



3. INSTALL COOLER COMPRESSOR ASSEMBLY (w/ Air Conditioning System)


    A118422
  1. Install the compressor with the 4 bolts.

    Torque:
    25 N*m{ 255 kgf*cm , 18 ft.*lbf }

  1. Connect the compressor connector.



4. INSTALL FAN BELT ADJUSTING BAR (w/o Air Conditioning System)


    A123775
  1. Install the fan belt adjusting bar with the 2 bolts.

    Torque:
    45 N*m{ 460 kgf*cm , 33 ft.*lbf }



    A123774
  1. Temporarily install the bolt.



5. INSTALL FAN & GENERATOR V BELT (w/o Air Conditioning System)


    A115631E01
  1. Install the V belt.

  1. Using a bar, adjust the tension of the V belt.

  1. Tighten the bolts A and B.

    Torque:
    Bolt A:
    75 N*m{ 765 kgf*cm , 55 ft.*lbf }
    Bolt B:
    18 N*m{ 185 kgf*cm , 13 ft.*lbf }

  1. Check the deflection of the V belt (Click here).



6. INSTALL FAN AND GENERATOR V BELT (w/ Air Conditioning System)


G035153E01
  1. Use the pulley set bolt of the tensioner to rotate the tensioner pulley clockwise, and then install the V belt.

    NOTICE:
    Make sure that the V belt is set properly at each pulley.



    A114802E01
  1. Make sure that the indicator mark of the tensioner is within range A, as shown in the illustration.



7. INSTALL COOLER COMPRESSOR V BELT (w/ Air Conditioning System)


    A121093E02
  1. Install the V belt.

  1. Tightening the bolt B, adjust the tension of the V belt.

  1. Tighten nut A.

    Torque:
    39 N*m{ 400 kgf*cm , 29 ft.*lbf }

  1. Check the tension of the V belt (Click here).



8. INSTALL AIR CLEANER ASSEMBLY


    A118427
  1. Install the cleaner with the 2 bolts.

    Torque:
    14 N*m{ 143 kgf*cm , 10 ft.*lbf }

  1. Connect the connector to the IAT sensor.

  1. Connect the hose clamp.



9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


10. PERFORM INITIALIZATION
  1. Perform initialization (Click here).

    NOTICE:
    Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.