Home › ENGINE ยท 2KD-FTV › CHARGING › GENERATOR (for BOSCH Made)

GENERATOR (for BOSCH Made) > INSTALLATION

for Preparation Click here



1. INSTALL GENERATOR ASSEMBLY


A111821E01
  1. Install the generator and with the 2 bolts.

    Torque:
    62 N*m{ 632 kgf*cm , 46 ft.*lbf } for bolt A
    25 N*m{ 255 kgf*cm , 18 ft.*lbf } for bolt B

  1. Install the generator wire with the nut.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }

  1. Connect the generator connector.



2. INSTALL FAN AND GENERATOR V BELT


G035153E01
  1. Use the pulley set bolt of the tensioner to rotate the tensioner pulley clockwise, and then install the V belt.

    NOTICE:
    Make sure that the V belt is set properly at each pulley.



    A114802E01
  1. Make sure that the indicator mark of the tensioner is within range A, as shown in the illustration.



3. INSTALL AIR CLEANER ASSEMBLY
  1. Install the cleaner with the 2 bolts.

    Torque:
    14 N*m{ 143 kgf*cm , 10 ft.*lbf }

  1. w/ Intake Air Temperature Sensor:
    Connect the connector to the intake air temperature sensor.

  1. w/ Mass Air Flow Meter:
    Connect the connector to the mass air flow meter.

  1. Tighten the hose clamp.

  1. for Ventilation Hose Type:
    Connect the ventilation hose.



4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE: