Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 1TR-FE STARTING

1TR-FE STARTING > SERVICE DATA



for 1.0 kW Type 
Starter
No-load characteristics current
90 A or less at 11.5 V
Starter armature
Segments
Below 1 Ω
Segment - Coil core
10 kΩ or higher
Maximum circle runout
0.05 mm (0.0020 in.)
Standard diameter
28 mm (1.10 in.)
Maximum diameter
27 mm (1.06 in.)
Standard depth
0.6 mm (0.024 in.)
Minimum depth
0.2 mm (0.008 in.)
Brush length
Standard length
14.0 mm (0.551 in.)
Minimum length
9.0 mm (0.354 in.)
Lead wire - Field coil brush lead
Below 1 Ω
Field coil brush lead - Starter yoke body
10 kΩ or higher
Positive brush - Negative brush
10 kΩ or higher
Brush spring
Standard spring load
13.7 to 17.6 N
(1.4 to 1.8 kgf, 3.1 to 4.0 lbf)
Minimum spring load
8.8 N
(0.9 kgf, 2.0 lbf)
Magnet starter body
Terminal 50 - Terminal C
Below 1 Ω
Terminal 50 - Body
Below 2 Ω

for 1.7 kW Type 
Starter
No-load characteristics current
90 A or less at 10.9 V
Starter armature
Segments
2.7 to 3.3 Ω
Segment - Coil core
10 kΩ or higher
Standard runout
0.02 mm (0.0008 in.)
Maximum runout
0.04 mm (0.0016 in.)
Standard diameter
32.2 mm (1.2677 in.)
Maximum diameter
31.1 mm (1.2244 in.)
Standard undercut depth
0.9 mm 0.0354 in.)
Minimum undercut depth
0.4 mm (0.0157 in.)
Brush length
Standard length
11.3 mm (0.4449 in.))
Minimum length
7.5 mm (0.2953 in. )
Brush holder
Tester connection
A - B
10 kΩ or higher
Tester connection
A - C
10 kΩ or higher
Tester connection
A - D
Below 1 Ω
Tester connection
B - C
Below 1 Ω
Tester connection
B - D
10 kΩ or higher
Tester connection
C - D
10 kΩ or higher
Magnet starter switch
Terminal 50 - Terminal C
Below 1 Ω
Terminal 50 - Body
Below 2 Ω