Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 2KD-FTV INTAKE

2KD-FTV INTAKE > SERVICE DATA



w/ EGR cooler 
Manifold absolute pressure sensor
Condition
Tester connection
Specified Condition
ECM output voltage
T9-3 (VC (+)) - T9-1 (E2 (-))
4.75 to 5.25 V
Applied vacuum
-
-
13.3 kPa (100 mmHg, 3.94 in.Hg)
E7-28 (PIM) - E8-28 (E2)
0.08 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.23 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.39 V
Applied pressure
-
-
19. 6 kPa (0.20 mmHg, 2.84 in.Hg)
E7-28 (PIM) - E8-28 (E2)
0.15 V
39.2 kPa (0.40 mmHg, 5.69 in.Hg)
0.38 V
58.8 kPa (0.60 mmHg, 8.53 in.Hg)
0.60 V
78.5 kPa (0.80 mmHg, 11.4 in.Hg)
0.82 V
98.0 kPa (1.00 mmHg, 14.2 in.Hg)
1.05 V
Turbocharger pressure
for Vacuum Controlled Actuator
Condition
Specified Condition
Engine speed (approximately 4,600 rpm)
53 to 83 kPa (0.54 to 0.84 kgf/cm2, 7.6 to 12.0 psi)
for Variable Nozzle Vane Turbocharger
Condition
Specified Condition
Engine speed (approximately 4,600 rpm)
10 to 40 kPa (0.10 to 0.41 kgf/cm2, 1.5 to 5.8 psi)
Turbocharger
for Vacuum Controlled Actuator
Condition
Specified Condition
Maximum axial play of turbine shaft
0.08 mm (0.0031 in.)
Maximum radial play of turbine shaft
0.110 mm (0.0043 in.)
Actuator and waste gate valve operation
(Part No. : Valve opening pressure)
17201-0L030, 17201-30120:
114 kPa (1.16 kgf*cm2, 16.5 psi)
17201-0L050:
123 kPa (1.25 kgf*cm2, 17.8 psi)
17201-30141:
135 kPa (1.37 kgf*cm2, 19.5 psi)
for Variable Nozzle Vane Turbocharger
Condition
Specified Condition
Maximum axial play of turbine shaft
0.11 mm (0.0043 in.)
Maximum radial play of turbine shaft
0.112 mm (0.0044 in.)

w/o EGR cooler 
Manifold absolute pressure sensor
Condition
Tester connection
Specified Condition
ECM output voltage
T9-3 (VC (+)) - T9-1 (E2 (-))
4.75 to 5.25 V
Applied vacuum
-
-
13.3 kPa (100 mmHg, 3.94 in.Hg)
E7-28 (PIM) - E8-28 (E2)
0.1 to 0.4 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.2 to 0.6 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.4 to 0.8 V
Applied pressure
-
-
19. 6 kPa (0.20 mmHg, 2.84 in.Hg)
E7-28 (PIM) - E8-28 (E2)
0.1 to 0.4 V
39.2 kPa (0.40 mmHg, 5.69 in.Hg)
0.4 to 0.7 V
58.8 kPa (0.60 mmHg, 8.53 in.Hg)
0.7 to 1.0 V
78.5 kPa (0.80 mmHg, 11.4 in.Hg)
1.0 to 1.3 V
98.0 kPa (1.00 mmHg, 14.2 in.Hg)
1.3 to 1.6 V
Turbocharger pressure
Condition
Specified Condition
Engine speed (approximately 4,600 rpm)
53 to 83 kPa (0.54 to 0.84 kgf/cm2, 7.6 to 12.0 psi)
Turbocharger
Condition
Specified Condition
Maximum axial play of turbine shaft
0.08 mm (0.0031 in.)
Maximum radial play of turbine shaft
0.110 mm (0.0043 in.)
Actuator and waste gate valve operation
(Part No. : Valve opening pressure)
17201-0L030, 17201-30120:
114 kPa (1.16 kgf*cm2, 16.5 psi)
17201-0L050:
123 kPa (1.25 kgf*cm2, 17.8 psi)
17201-30141:
135 kPa (1.37 kgf*cm2, 19.5 psi)