DTC P0405 Exhaust Gas Recirculation Sensor "A" Circuit Low |
DTC P0406 Exhaust Gas Recirculation Sensor "A" Circuit High |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0405 | EGR valve position sensor output voltage is less than 0.1 V for more than 5 seconds (1 trip detection logic) |
|
| P0406 | EGR valve position sensor output voltage is more than 4.9 V for more than 5 seconds (1 trip detection logic) |
|
| Result | Condition |
| Changes between 0.3 to 4.2 V | Normal |
| Less than 0.1 V | P0405 (Low input voltage) |
| More than 4.9 V | P0406 (High input voltage) |


| 1.CHECK ECM (VC VOLTAGE) |
![]() |
Disconnect the E2 EGR valve position sensor connector.
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| E2-1 (VC) - E2-2 (E2) | 4.5 to 5.5 V |
Reconnect the EGR valve position sensor connector.
|
| ||||
| OK | |
| 2.INSPECT EGR VALVE POSITION SENSOR (RESISTANCE) |
Inspect the EGR valve position sensor .
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (EGR VALVE POSITION SENSOR - ECM) |
![]() |
Disconnect the E2 sensor connector.
Disconnect the E7 and E8 ECM connectors.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| E2-1 (VC) - E8-18 (VC) | Below 1 Ω |
| E2-3 (EGLS) - E7-33 (EGLS) | Below 1 Ω |
| E2-2 (E2) - E8-28 (E2) | Below 1 Ω |
| Tester Connection | Specified Condition |
| E2-1 (VC) or E8-18 (VC) - Body ground | 10 kΩ or higher |
| E2-3 (EGLS) or E7-33 (EGLS) - Body ground | 10 kΩ or higher |
| E2-2 (E2) or E8-28 (E2) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||