Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › VISCOUS HEATER MAGNET CLUTCH (for Cold Area)

VISCOUS HEATER MAGNET CLUTCH (for Cold Area) > INSPECTION

for Preparation Click here



1. INSPECT MAGNETIC CLUTCH CLEARANCE


    I034101E02
  1. Place the viscous with magnet clutch heater in vise.

  1. Set the dial indicator to the magnet clutch hub.

  1. Connect the battery positive (+) lead to the terminal 1 of magnet clutch connector and the (-) lead to the ground wire. Turn on and off the magnet clutch and measure the clearance.

    Standard clearance:
    0.35 to 0.60 mm ( 0.33 to 0.023 in.)

    If the measured value is out the standard range, remove the magnet clutch washers.

    NOTICE:
    Adjustment shall be performed with 3 or less magnet clutch washers.