DTC B1835/58 Short in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1836/58 Open in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1837/58 Short to GND in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1838/58 Short to B+ in Front Passenger Side Curtain Shield Squib Circuit |
| DTC Code | Detection Condition | Trouble Area |
| B1835/58 | When all conditions below are met:
|
|
| B1836/58 | When all conditions below are met:
|
|
| B1837/58 | When all conditions below are met:
|
|
| B1838/58 | When all conditions below are met:
|
|


| 1.CHECK VEHICLE CONDITION |
Check vehicle condition.
| Result | Proceed to |
| for LHD | A |
| for RHD | B |
|
| ||||
| A | |
| 2.CHECK CURTAIN SHIELD AIRBAG RH (CURTAIN SHIELD SQUIB RH) |
![]() |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connector from the curtain shield airbag RH.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch OFF.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 3.CHECK CONNECTOR |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the No. 2 floor wire connector (on the curtain shield airbag RH side) is not damaged.
|
| ||||
| OK | |
| 4.CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB RH CIRCUIT) |
![]() |
Disconnect the connectors from the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C21-2 (ICR-) - Body ground | Ignition switch ON | Below 1 V |
| C21-1 (ICR+) - Body ground |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C21-2 (ICR-) - C21-1 (ICR+) | Always | Below 1 Ω |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C21-2 (ICR-) - C21-1 (ICR+) | Always | 1 MΩ or higher |
| C21-2 (ICR-) - Body ground | ||
| C21-1 (ICR+) - Body ground |
|
| ||||
| OK | |
| 5.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Connect the connectors to the curtain shield airbag RH and the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch OFF.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 6.CHECK CURTAIN SHIELD AIRBAG ASSEMBLY LH (CURTAIN SHIELD SQUIB LH) |
![]() |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connector from the curtain shield airbag RH.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch OFF.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 7.CHECK CONNECTOR |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the floor wire connector (on the curtain shield airbag LH side) is not damaged.
|
| ||||
| OK | |
| 8.CHECK FLOOR WIRE |
![]() |
Disconnect the connectors from the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C22-2 (ICL-) - Body ground | Ignition switch ON | Below 1 V |
| C22-1 (ICL+) - Body ground |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C22-2 (ICL-) - C22-1 (ICL+) | Always | Below 1 Ω |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C22-2 (ICL-) - C22-1 (ICL+) | Always | 1 MΩ or higher |
| C22-2 (ICL-) - Body ground | ||
| C22-1 (ICL+) - Body ground |
|
| ||||
| OK | |
| 9.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Connect the connectors to the curtain shield airbag LH and the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch OFF.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||