1KD-FTV EMISSION CONTROL > SERVICE DATA |
| Vacuum switching valve (for EGR Cut) | 1 - 2 | 37 to 44 Ω at 20°C (68°F) |
| 1 - Body ground 2 - Body ground | 1 MΩ or higher | |
| Vacuum regulating valve (for EGR) | 1 - 2 | 11 to 13 Ω at 20°C (68°F) |
| 1 - Body ground 2 - Body ground | 10 MΩ or higher |
| Electric EGR control valve | 1(VC) - 2(E2) | - | 4.0 to 6.0 kΩ at 20°C (68°F) |
| Terminal 3 (EGLS) - 2 (E2) | Fully opened | 4.1 kΩ at 20°C (68°F) | |
| Terminal 3 (EGLS) - 2 (E2) | Fully closed | 0.8 kΩ at 20°C (68°F) | |
| No. 1 vacuum switching valve (for EGR Cut) | 1 - 2 | 37 to 44 Ω at 20°C (68°F) | |
| 1 - Body Ground 2 - Body Ground | 1 MΩ or higher | ||
| No. 2 vacuum switching valve (for No. 2 EGR) | 1 - 2 | 37 to 44 Ω at 20°C (68°F) | |
| 1 - Body Ground 2 - Body Ground | 1 MΩ or higher | ||
| Electric vacuum regulating valve (for E-EGR) | 1 - 2 | 11 to 13 Ω at 20°C (68°F) | |
| 1 - Body Ground 2 - Body Ground | 10 MΩ or higher | ||