Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > ACTUATOR CHECK

for Preparation Click here



CHECK ACTUATOR


    E165583
  1. Turn the ignition switch to ON while pressing the A/C control AUTO and recirculation switches simultaneously.



  2. E165589
  3. After entering the DTC check mode (Sensor Check Mode), press the recirculation switch.

  4. Each damper, motor and relay will operate during the actuator check, which consists of various inspections labeled by step numbers (see the "Step No." column in the table below). The step numbers will advance from 1 to 10 at 1 second intervals. At each interval, check the temperature on the display and check the air flow with your hand.

    HINT:
    1. If manual switching of the step number display is desired, press the front DEF switch. This will stop the automatic progression of the step numbers. The step number can then be advanced manually by pressing the front DEF switch.
    2. Codes are displayed as numbers from lowest to highest.
    3. To cancel the check mode, press the OFF switch.


    Air Conditioning Unit 
    Step No.
    Display Code
    Conditions
    Blower Level
    Air Flow Vent
    Air Inlet Control Damper
    Air Mix Damper Position
    Magnet Clutch
    1
    0
    0
    FACE
    FRESH
    COOL side (0% open)
    OFF
    2
    1
    1
    FACE
    FRESH
    COOL side (0% open)
    OFF
    3
    2
    16
    FACE
    RECIRCULATION/FRESH
    (50%)
    COOL side (0% open)
    ON
    4
    3
    16
    FACE
    RECIRCULATION
    COOL side (0% open)
    ON
    5
    4
    16
    FACE
    RECIRCULATION
    COOL/HOT (50% open)
    ON
    6
    5
    16
    BI-LEVEL
    FRESH
    COOL/HOT (50% open)
    ON
    7
    6
    16
    FOOT
    FRESH
    HOT side (100% open)
    ON
    8
    7
    16
    FOOT
    RECIRCULATION
    HOT side (100% open)
    ON
    9
    8
    16
    FOOT/DEF
    FRESH
    HOT side (100% open)
    ON
    10
    9
    31
    DEF
    FRESH
    HOT side (100% open)
    ON