HEATER SWITCH > INSPECTION |
| 1. INSPECT HEATER SWITCH ASSEMBLY |
![]() |
Inspect the heater switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 4(SW) - 1(E) | ON | Below 1 Ω |
| 4(SW) - 1(E) | OFF | 10 kΩ or higher |
Inspect the switch illumination.
Apply battery voltage between the terminals of the light, and check the operation of the light.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal - 3(ILL+) Battery negative (-) → Terminal - 6(ILL-) | Light comes on |
Inspect the switch indicator illumination.
Apply battery voltage between the terminals of the light, and check the operation of the light.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 5(IND+) Battery negative (-) → Terminal 8(IND-) | Light comes on |