Home › ENGINE · 2KD-FTV › ENGINE CONTROL SYSTEM › ECD SYSTEM (w/ EGR Cooler)

ECD SYSTEM (w/ EGR Cooler) > MIL Circuit

for Preparation Click here


DESCRIPTION

The MIL (Malfunction Indicator Lamp) is used to indicate vehicle malfunction detections by the ECM.
By turning the ignition switch ON, power is supplied to the MIL circuit, and the ECM provides the circuit ground which illuminates the MIL.
The MIL operation can be checked visually: When the ignition switch is first turned ON, the MIL should be illuminated and should then turn OFF. If the MIL remains illuminated or is not illuminated, conduct the following troubleshooting procedure using an intelligent tester.

WIRING DIAGRAM


A118970E04


INSPECTION PROCEDURE

NOTICE:
If the ECM is replaced, the new ECM needs registration (Click here) and initialization (Click here).

1.CHECK THAT MIL IS ILLUMINATED
  1. Perform troubleshooting in accordance with the chart below.


Result:

MIL Condition
Proceed to
MIL remains ON
A
MIL does not illuminate
B



B
Go to step 4
A


2.CHECK WHETHER MIL TURNS OFF
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch ON.

  1. Turn the tester ON.

  1. Check whether any DTCs have been stored. Note them down if necessary.

  1. Clear DTCs (Click here).

  1. Check if the MIL turns off.

    OK:
    MIL should turn off.



OK
DTC CHART
NG


3.CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT IN WIRE HARNESS)


    A065748E54
  1. Disconnect the E5 ECM connector.

  1. Turn the ignition switch ON.

  1. Check that MIL is not illuminated.

    OK:
    MIL does not illuminate.

  1. Reconnect the ECM connector.



NG
Go to step 6
OK

REPLACE ECM 

4.CHECK THAT MIL IS ILLUMINATED
  1. Check if the MIL illuminated when the ignition switch is turns ON.

    OK:
    MIL should be illuminated.



OK
SYSTEM OK
NG


5.CHECK THAT ENGINE STARTS
  1. Turn the ignition switch ON.

  1. Start the engine.

    Result:

    Result
    Proceed To
    Engine starts
    A
    Engine does not start*
    B

    HINT:
    *: An intelligent tester cannot communicate with the ECM.



B
GO TO VC OUTPUT CIRCUIT
A


6.CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)


    A155935E01
  1. Disconnect the C8 combination meter connector.

  1. Disconnect the E5 ECM connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    C8-39 - W (E5-12)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    C8-39 or W (E5-12) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (COMBINATION METER - ECM)
OK

REPLACE COMBINATION METER ASSEMBLY