VACUUM PUMP (for 5L-E) > INSTALLATION |
| 1. INSTALL VACUUM PUMP ASSEMBLY |
![]() |
Align the matchmarks and install the vacuum pump to the generator with the 4 bolts.
| 2. INSTALL GENERATOR WITH VACUUM PUMP ASSEMBLY |
| 3. CHECK VACUUM PUMP ASSEMBLY |
Disconnect the vacuum hose from the vacuum pump.
![]() |
Connect the hose of a vacuum gauge to the pump.
Insert a plug into the other hose of the gauge.
Start the engine and warm it up for more than 2 minutes.
With the engine idling, measure the negative pressure of the pump.
Remove the gauge from the pump.
Connect the hose to the pump with the clip.