Home › TRANSMISSION · A750F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM (for 1KD-FTV)

DTC    P2759    Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

for Preparation Click here


DESCRIPTION

The amount of current flow to the solenoid is controlled by the duty ratio* of the TCM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.
C110339E15
*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF times (A + B).
Duty Ratio (%) = A/ (A + B) x 100

DTC Code
DTC Detection Condition
Trouble Area
P2759
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic)
  1. Open or short in shift solenoid valve SLU circuit
  2. Shift solenoid valve SLU
  3. TCM

MONITOR DESCRIPTION

When an open or short in a shift solenoid valve SLU circuit is detected, the TCM determines that there is a malfunction. The TCM will illuminate the MIL and store this DTC.

WIRING DIAGRAM


C161203E56


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)


    C159421E53
  1. Disconnect the E1 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    13 (SLU+) - 5 (SLU-)
    20°C (68°F)
    5.0 to 5.6 Ω
    13 (SLU+) - Body ground
    20°C (68°F)
    10 kΩ or higher
    5 (SLU-) - Body ground
    20°C (68°F)
    10 kΩ or higher



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)


    C191544E33
  1. Disconnect the T19 TCM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    T19-22 (SLU+) - T19-21 (SLU-)
    20°C (68°F)
    5.0 to 5.6 Ω
    T19-22 (SLU+) - Body ground
    20°C (68°F)
    10 kΩ or higher
    T19-21 (SLU-) - Body ground
    20°C (68°F)
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE TCM 

3.INSPECT SHIFT SOLENOID VALVE SLU


    C162477E02
  1. Remove the shift solenoid valve SLU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise



NG
REPLACE SHIFT SOLENOID VALVE SLU
OK

REPAIR OR REPLACE TRANSMISSION WIRE