Home › TRANSMISSION · A750F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM (for 1KD-FTV)

DTC    P0778    Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which is controlled by the TCM. If an open or short circuit occurs in the shift solenoid valves, the TCM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely (Click here).

DTC Code
DTC Detection Condition
Trouble Area
P0778
TCM checks for an open or short in shift solenoid valve SL2 circuit while driving and shifting between 4th and 5th gear (1 trip detection logic)
Output signal duty equal to 100%

HINT:
SL2 output signal duty is less than 100% under normal conditions

  1. Open or short in shift solenoid valve SL2 circuit
  2. Shift solenoid valve SL2
  3. TCM

MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The TCM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. Also, the TCM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In case of an open or short circuit, the TCM stops sending current to the circuit.
While driving and shifting between 4th and 5th gears, if the TCM detects an open or short in the shift solenoid valve SL2 circuit, the TCM determines that there is a malfunction (Click here).

WIRING DIAGRAM


C161203E54


INSPECTION PROCEDURE


HINT:
The shift solenoid valve SL2 turns ON/OFF normally when the shift lever is on D:

TCM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve SL2
ON
ON
ON
ON
OFF

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2)


    C159421E47
  1. Disconnect the E1 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    11 (SL2+) - 3 (SL2-)
    20°C (68°F)
    5.0 to 5.6 Ω
    11 (SL2+) - Body ground
    20°C (68°F)
    10 kΩ or higher
    3 (SL2-) - Body ground
    20°C (68°F)
    10 kΩ or higher



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)


    C191544E26
  1. Disconnect the T19 TCM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    T19-7 (SL2+) - T19-6 (SL2-)
    20°C (68°F)
    5.0 to 5.6 Ω
    T19-7 (SL2+) - Body ground
    20°C (68°F)
    10 kΩ or higher
    T19-6 (SL2-) - Body ground
    20°C (68°F)
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE TCM 

3.INSPECT SHIFT SOLENOID VALVE SL2


    C151311E17
  1. Remove the shift solenoid valve SL2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 1
    2. Battery negative (-) → Terminal 2
    Valve moves and makes an operating noise



NG
REPLACE SHIFT SOLENOID VALVE SL2
OK

REPAIR OR REPLACE TRANSMISSION WIRE