Home › TRANSMISSION · A343E AUTOMATIC TRANSMISSION › ATF TEMPERATURE SENSOR

ATF TEMPERATURE SENSOR > INSPECTION

for Preparation Click here



1. INSPECT AUTOMATIC TRANSMISSION FLUID TEMPERATURE SENSOR


C169604E02
  1. Measure the resistance of the temperature sensor.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    79 Ω to 156 kΩ
    1 - Body ground
    1 MΩ or higher
    2 - Body ground
    1 MΩ or higher

    HINT:
    If the resistance is out of the specified range for either of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.

    Standard resistance:
    ATF Temperature
    Specified Condition
    20°C (68°F)
    10.3 to 13.9 kΩ
    110°C (230°F)