Home › ENGINE · 5L-E › ENGINE CONTROL SYSTEM › ECD SYSTEM

ECD SYSTEM > TC and CG Terminal Circuit

for Preparation Click here


DESCRIPTION

Terminals TC and CG are located in the DLC3.
The DLC3 is located under the instrument panel under cover. When terminals TC and CG are connected, DTC in normal mode or test mode can be read from the Malfunction Indicator Lamp (MIL) in the combination meter.
Also, terminal SIL is located in the DLC3. This terminal is used by the M-OBD communication with intelligent tester.

WIRING DIAGRAM


A119281E01


INSPECTION PROCEDURE

1.CHECK DLC3 (CHECK VOLTAGE)


    A058596E03
  1. Measure the voltage of the DLC3 connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    D1-16 (BAT) - D1-4 (CG)
    9 to 14 V



NG
Go to step 3
OK


2.CHECK WIRE HARNESS (ECM - DLC3)


    A110543E03
  1. Disconnect the E20 ECM connector.

  1. Measure the resistance of the wire harness side connectors

    Standard resistance:
    Tester Connection
    Specified Condition
    D1-7 (SIL) - E20-15 (SIL)
    Below 1 Ω
    D1-13 (TC) - E20-4 (TC)
    Below 1 Ω
    E20-15 (SIL) - Body ground
    10 kΩ or higher
    E20-4 (TC) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECM 

3.CHECK DLC3


    A058596E04
  1. Measure the resistance of the DLC3 connector and body ground.

    Standard resistance:
    Tester Connection
    Specified Condition
    D1-4 (CG) - Body ground
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


4.INSPECT FUSE (OBD FUSE)


    A121708E01
  1. Remove the OBD fuse from the instrument panel junction block.

  1. Measure the resistance of the OBD fuse.

    Standard resistance:
    Tester Connection
    Specified Condition
    OBD fuse
    Below 1 Ω (continuity)



NG
CHECK FOR SHORT IN ALL HARNESSES AND COMPONENTS CONNECTED TO FUSE, AND REPLACE FUSE
OK

CHECK AND REPLACE HARNESS AND CONNECTOR (DLC3 - BATTERY)