Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    11    Room Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The cooler thermistor (A/C room temperature sensor) is installed in the instrument panel to detect the room temperature and control the heater and air conditioning AUTO function. The resistance of the cooler thermistor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies voltage (5 V) to the cooler thermistor and reads voltage changes as the resistance of the cooler thermistor changes.

DTC Code
Detection Item
Trouble Area
11
Open or short in room temperature sensor circuit
  1. Cooler thermistor (A/C room temperature sensor)
  2. Harness or connector
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E171023E01


INSPECTION PROCEDURE

1.INSPECT COOLER THERMISTOR (A/C ROOM TEMPERATURE SENSOR)


    E170940E01
  1. Remove the cooler thermistor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Even slightly touching the thermistor may change the resistance value. Be sure to hold the connector of the thermistor.
    2. When measuring the resistance, the thermistor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (Refer to the graph).



NG
REPLACE COOLER THERMISTOR (A/C ROOM TEMPERATURE SENSOR) (Click here)
OK


2.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (TR VOLTAGE)


    E170941E13
  1. Remove the air conditioning amplifier with its connectors still connected.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A38-18 (TR) - A38-13 (SG-3)
    Ignition switch ON
    Cabin temperature: 25°C (77°F)
    1.8 to 2.2 V
    Ignition switch ON
    Cabin temperature: 40°C (104°F)
    1.2 to 1.6 V

    HINT:
    As the temperature increases, the voltage decreases.

    Result 
    Result
    Proceed to
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    A
    OK (Checking from the DTC)
    B
    NG
    C



B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

C
Go to step 3
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

3.CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER)


    E170942E07
  1. Disconnect the A34 thermistor connector.

  1. Disconnect the A38 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A38-18 (TR) - A34-2
    Always
    Below 1 Ω
    A38-13 (SG-3) - A34-1
    A38-18 (TR) - Body ground
    Always
    10 kΩ or higher
    A38-13 (SG-3) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)