THEFT DETERRENT SYSTEM > ON-VEHICLE INSPECTION |
| 1. OUTLINE OF THEFT DETERRENT SYSTEM |
When the theft deterrent system detects that the vehicle is being tampered with, the system activates the alarm function.
The theft deterrent system has 4 states: disarmed state, arming preparation state, armed state and alarm sounding state.
Step 1: Disarmed state:
Step 2: Arming preparation state:
Step 3: Armed state:
Step 4: Alarm sounding state:
| Item | Alarm Method |
| Hazard warning lights | Flashing at approximately 0.35 seconds intervals |
| Horns | Sounding at approximately 0.4 seconds intervals |
| 2. ARMING MODE |
| System state | State switching condition | Go to |
| 1. Disarmed state (No key inserted into ignition key cylinder) | Performing the following will cause the system to enter the arming preparation state (at the same time, hazard warning lights flash and security horn sounds once):
| 2. Arming preparation state |
| 2. Arming Preparation state | Performing any of the following will cause the system to return to the disarmed state:
| 1. Disarmed state |
Performing the following will cause the system to enter the armed state:
| 3. Armed state | |
| 3. Armed state | Performing any of the following will cause the system to return to the disarmed state:
| 1. Disarmed state |
Performing any of the following will cause the system to enter the alarm sounding state:
| 4. Alarm sounding state* | |
| 4. Alarm sounding state* | Performing any of the following will cause the system to return to the disarmed state:
| 1. Disarmed state |
| When a theft attempt is detected, the hazard warning lights flash and the horns sound. The alarm sounding state operates for 27.5 seconds. | 3. Armed state |
| 3. SECURITY INDICATOR OUTPUT |
The theft warning ECU outputs a signal to cause flashing or illumination of the security indicator according to the status of the system.
| Condition | Security Indicator |
| Disarmed state | OFF (Immobiliser system not set) Blinking (Immobiliser system set) |
| Arming preparation state | ON |
| Armed state | Blinking |
| Alarm sounding state | ON |
| Time | Security Indicator |
| 0.2 seconds | ON |
| 1.8 seconds | OFF |
| 4. ALARM MEMORY FUNCTION |
The alarm memory function informs the user if the theft deterrent system entered the alarm sounding state while the user was away.
After the theft deterrent system is set, if the system enters the alarm sounding state and the alarm sounding state ends before the theft deterrent system is canceled by the user, the alarm memory function will operate. When the theft deterrent system is canceled by the user, the alarm memory function will flash the hazard warning lights 3 times at 0.35 seconds intervals.
| 5. STARTER CUT FUNCTION |
When the alarm is sounding, voltage to the starter is cut.