Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > PTC Heater Circuit

for Preparation Click here


DESCRIPTION

The PTC relays turn on when they receive a signal from the air conditioning amplifier. As a result, power is supplied to the PTC heater.

WIRING DIAGRAM


E170989E02


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.INSPECT PTC HEATER RELAY (NO. 1, NO. 2)


    E170990E01
  1. Remove the No. 1 PTC heater relay and No. 2 PTC heater relay.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    Battery voltage is applied between terminals 1 and 2
    Below 1 Ω



NG
REPLACE PTC HEATER RELAY
OK


2.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


    E170988E02
  1. Remove the air conditioning amplifier with its connectors still connected.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A36-1 (PTC1) - Body ground
    Ignition switch ON
    Generator is operating
    Temperature switch Max. HOT
    Coolant temperature:
    Below 65°C (149°F)
    Ambient temperature:
    Below 10°C (50°F)
    Power heater switch ON
    Blower switch ON (LO)
    11 to 14 V
    A36-2 (PTC2) - Body ground



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - PTC HEATER)


    E170991E01
  1. Remove the No. 1 PTC heater relay and No. 2 PTC heater relay.

  1. Disconnect the P17 heater connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P18-5 - P17-2 (B)
    Always
    Below 1 Ω
    P19-5 - P17-1 (B)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (PTC HEATER - BODY GROUND)


    E170992E01
  1. Disconnect the P16 heater connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P16-1 (E) - Body ground
    Always
    Below 1 Ω
    P16-2 (E) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK PTC HEATER


    E140255E04
  1. Disconnect the P17 and P16 PTC heater connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P17-1 (B) - P16-1 (E)
    Always
    Below 1 Ω
    P17-2 (B) - P16-2 (E)



NG
REPLACE PTC HEATER
OK


6.CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - AMPLIFIER AND BODY GROUND)


    E170993E01
  1. Remove the No. 1 PTC heater relay and No. 2 PTC heater relay.

  1. Disconnect the A36 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P18-2 - A36-1 (PTC1)
    Always
    Below 1 Ω
    P19-2 - A36-2 (PTC2)
    P18-1 - Body ground
    Always
    Below 1 Ω
    P19-1 - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)