AIR CONDITIONING SYSTEM (for Cold Area) > TERMINALS OF ECU |
| CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (w/ HOT GAS HEATER) |

Disconnect the A9 A/C amplifier connector.
Measure the voltage and resistance of the wire harness side connector.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| +B (A9-40) - GND (A9-29) | L-Y - L | For memory backup | Always | 10 to 14 V |
| IG (A9-20) - GND (A9-29) | R-L - L | Power source (IG) | Ignition switch OFF | Below 1 V |
| IG (A9-20) - GND (A9-29) | R-L - L | Power source (IG) | Ignition switch ON | 10 to 14 V |
| GND (A9-29) - Body ground | L - Body ground | Ground | Always | Below 1 Ω |
| ACON (A9-8) - GND (A9-29) | R-G - L | A/C switch signal | A/C switch OFF | Below 1 V |
| ACON (A9-8) - GND (A9-29) | R-G - L | A/C switch signal | Ignition switch START Blower switch ON A/C switch ON | 10 to 14 V |
| IND (A9-9) - GND (A9-29) | R-L - L | A/C indicator light signal | A/C switch OFF | Below 1 V |
| IND (A9-9) - GND (A9-29) | R-L - L | A/C indicator light signal | Ignition switch START Blower switch ON A/C switch ON | 10 to 14 V |
| BLW (MHOT) (A9-38) - GND (A9-29) | R-L - L | Max HOT switch signal | Temperature control knob: Max HOT | Below 1 Ω |
| BLW (MHOT) (A9-38) - GND (A9-29) | R-L - L | Max HOT switch signal | Temperature control knob: Max HOT | 10k Ω or higher |
| POWHTR (A9-5) - GND (A9-29) | L-O - L | Heater switch signal | Heater switch ON | Below 1 Ω |
| POWHTR (A9-5) - GND (A9-29) | L-O - L | Heater switch signal | Heater switch OFF | 10k Ω or higher |
| MGC (A9-19) - GND (A9-29) | B - L | Magnet clutch relay signal | Ignition switch START Blower switch ON | 10 to 14 V |
| MGC (A9-19) - GND (A9-29) | B - L | Magnet clutch relay signal | Ignition switch START Blower switch OFF | Below 1 V |
| TAIL (A9-7) - GND (A9-29) | G - L | Light control switch signal | Light control switch ON | 10 to 14 V |
| TAIL (A9-7) - GND (A9-29) | G - L | Light control switch signal | Light control switch OFF | Below 1 V |
Reconnect the A9 connector.
Measure the voltage and resistance of the connector.
| Symbols (Terminal NO.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| S5 (A9-13) - SG-3 (A9-12) | R-B - BR-Y | Power supply for pressure sensor | Ignition switch ON | 4.5 to 5.5 V |
| PRE (A9-4) - SG-3 (A9-12) | BR - BR-Y | A/C pressure sensor signal | Ignition switch START Refrigerant pressure normal: 0.18 MPa (1.9 kgf/cm2, 26 psi) to 3.03 MPa (31.0 kgf/cm2, 440 psi) Blower switch ON A/C switch ON | 0.74 to 4.66 V |
| PRE (A9-4) - SG-3 (A9-12) | BR - BR-Y | A/C pressure sensor signal | Ignition switch START Blower switch ON A/C switch ON Refrigerant pressure abnormal: pressure less than 0.18 MPa (1.9 kgf/cm2, 26 psi) | Below 0.74 V |
| PRE (A9-4) - SG-3 (A9-12) | BR - BR-Y | A/C pressure sensor signal | Ignition switch START Blower switch ON A/C switch ON Refrigerant pressure abnormal: pressure more than 3.03 MPa (31.0 kgf/cm2, 440 psi) | Above 4.66 V |
| TAM (A9-25) - SG-3 (A9-12) | W-G - BR-Y | Ambient temperature sensor signal | Ignition switch ON Ambient temperature is 25 °C (77°F) | 1.35 to 1.75 V |
| SG-3 (A9-12) - Body ground | BR-Y - Body ground | Ground for Ambient temperature sensor and pressure sensor | Always | Below 1 Ω |
| MGC (A9-19) - GND (A9-29) | B - L | Magnet clutch signal | Ignition switch START Magnet clutch is engaged | 10 to 14 V |
| MGC (A9-19) - GND (A9-29) | B - L | Magnet clutch signal | Ignition switch START Magnet clutch is not engaged | Below 1 V |
| TE (A9-24) - SG-1 (A9-31) | G - P | A/C evaporator temperature sensor signal | Ignition switch ON Evaporator temperature is 0°C (32°F) | 2.0 to 2.4 V |
| TE (A9-24) - SG-1 (A9-31) | G - P | A/C evaporator temperature sensor signal | Ignition switch ON Evaporator temperature is 15 °C (59°F) | 1.4 to 1.8 V |
| SG-1 (A9-31) - Body ground | P - Body ground | Ground for A/C evaporator temperature sensor | Always | Below 1 Ω |
| ACT (A9-39) - GND (A9-29) | R-L - L | Magnet on permit signal | Ignition switch START Blower switch OFF A/C switch OFF | Below 1 V |
| ACT (A9-39) - GND (A9-29) | R-L - L | Magnet on permit signal | Ignition switch START Blower switch ON A/C switch ON | 10 to 14 V |
| AC1 (A9-39) - GND (A9-29) | Y - L | Idle-up request signal | Ignition switch START Magnet clutch is not engaged | Below 1 V |
| AC1 (A9-39) - GND (A9-29) | Y - L | Idle-up request signal | Ignition switch START Magnet clutch is engaged | 10 to 14 V |
| BLW (MHOT) (A9-38) - GND (A9-29) | R-1 - L | Max HOT switch signal | Ignition switch ON Temperature control knob: Max HOT | 10 to 14 V |
| BLW (MHOT) (A9-38) - GND (A9-29) | R-1 - L | Max HOT switch signal | Ignition switch ON Temperature control knob: except Max HOT | Below 1 V |
| POWHTR (A9-5) - GND (A9-29) | L-O - L | Heater switch input signal | Ignition switch START Heater switch ON Temperature control knob: Max HOT Blower switch ON Coolant temperature 65 °C (149°F) or lower | Below 1 V |
| POWHTR (A9-5) - GND (A9-29) | L-O - L | Heater switch input signal | Ignition switch START Temperature control knob: except Max HOT Heater switch OFF Blower switch ON Coolant temperature 65 °C (149°F) or lower | 10 to 14 V |
| SWIN (A9-15) - GND (A9-29) | P - L | Heater switch indicator light signal | Ignition switch START Temperature control knob: Max HOT Heater switch ON Blower switch ON Coolant temperature 65 °C (149°F) or lower | Below 1 V |
| SWIN (A9-15) - GND (A9-29) | P - L | Heater switch indicator light signal | Ignition switch START Temperature control knob: except Max HOT Heater switch OFF Blower switch ON Coolant temperature 65 °C (149°F) or lower | 10 to 14 V |
| MGV (A9-17) - GND (A9-29) | Y-B - L | Magnetic valve operating signal | Ignition switch ON | 10 to 14 V |
| MGV (A9-17) - GND (A9-29) | G - L | Magnetic valve operating signal | Ignition switch START Temperature Control knob: Max HOT A/C switch ON Blower switch ON Heater switch ON Coolant temperature 65 °C (149°F) or lower | Below 1 V |
| ALT (A9-37) - GND (A9-29) | G - L | Generator | Engine running | Pulse generation |
| RPTC (A9-26) - GND (A9-29) | L-W - L | Heater switch output signal | Ignition switch START Temperature Control knob: Max HOT Heater switch ON Coolant temperature 65 °C (149°F) or lower Blower switch ON | 10 to 14 V |
| RPTC (A9-26) - GND (A9-29) | L-W - L | Heater switch output signal | Ignition switch START Temperature Control knob: Max HOT Heater switch OFF Coolant temperature 65 °C (149°F) or lower Blower switch ON | Below 1 V |
| TW (A9-32) - GND (A9-29) | P - L | Water temperature signal | Ignition switch ON | Pulse generation |
| TACO (A9-33) - GND (A9-29) | B-W - L | Tachometer signal | Engine running | Pulse generation (see waveform 1) |
| PTC1 (A9-3) - GND (A9-29) | R-W - L | PTC heater relay signal | Ignition switch START Heater switch ON Temperature Control knob: Max HOT Coolant temperature 65 °C (149°F) or lower Blower switch ON | Below 1 V |
| PTC1 (A9-3) - GND (A9-29) | GR - L | PTC heater relay signal | Ignition switch START Heater switch OFF Temperature Control knob: Max HOT Coolant temperature 65 °C (149°F) or lower Blower switch ON | 10 to 14 V |
| PTC2 (A9-2) - GND (A9-29) | GR - L | PTC heater relay signal | Ignition switch START Heater switch ON Temperature Control knob: Max HOT Coolant temperature 65 °C (149°F) or lower Blower switch ON | Below 1 V |
| PTC2 (A9-2) - GND (A9-29) | GR - L | PTC heater relay signal | Ignition switch START Heater switch OFF Temperature Control knob: Max HOT Coolant temperature 65 °C (149°F) or lower Blower switch ON | 10 to 14 V |
![]() |
Inspect using an oscilloscope.
Waveform 1 (Reference)
| Item | Content |
| Symbols (Terminal No.) | TACO (A9-33) - GND (A9-29) |
| Tool Setting | 5 V/DIV., 20 msec./DIV. |
| Condition | Engine idling |
| CHECK HEATER AMPLIFIER ASSEMBLY (w/ Viscous Heater) |

Disconnect the V6 viscous heater amplifier connector.
Measure the voltage and resistance of the wire harness side connector.
| Symbols (Terminal NO.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| +B (V6-9) - GND (V6-15) | L-Y - L | Viscous heater MGC power supply | Always | 10 to 14 V |
| IG (V6-1) - GND (V6-15) | R-L- L | Power source (IG) | Ignition switch OFF | Below 1 V |
| IG (V6-1) - GND (V6-15) | R-L- L | Power source (IG) | Ignition switch ON | 10 to 14 V |
| GND (V6-15) - Body ground | L - Body ground | Ground | Always | Below 1 Ω |
| BLW (V6-2) - GND (V6-15) | R-L - L | Max HOT switch signal | Temperature control knob: Max HOT | Below 1 Ω |
| BLW (V6-2) - GND (V6-15) | R-L - L | Max HOT switch signal | Temperature control knob: except Max HOT | 10k Ω or higher |
| HLS (V6-10) - GND (V6-15) | G - L | Light control switch signal | Light control switch ON | 10 to 14 V |
| HLS (V6-10) - GND (V6-15) | G - L | Light control switch signal | Light control switch OFF | Below 1 Ω |
Reconnect the V6 viscous heater amplifier connector.
Measure the voltage and resistance of the wire harness side connector
| Symbols (Terminal NO.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| MGCA (V6-18) - GND (V6-15) | B -L | Magnet clutch signal | Ignition switch START Magnet clutch is engaged | Below 1 V |
| MGCA (V6-18) - GND (V6-15) | B -L | Magnet clutch signal | Ignition switch START Magnet clutch is not engaged | 10 to 14 V |
| ACT (V6-12) - GND (V6-15) | R-L - L*1 V - L*2 | Viscous heater permit signal | Ignition switch START Heater switch ON Temperature control knob: Max HOT Blower switch ON Coolant temperature 65 °C (149°F) or more | Below 1 V |
| ACT (V6-12) - GND (V6-15) | R-L - L*1 V - L*2 | Viscous heater permit signal | Ignition switch START Heater switch OFF Temperature control knob: except Max HOT Blower switch OFF Coolant temperature 65 °C (149°F) or more | 10 to 14 V |
| AC2 (V6-5) - GND (V6-15) | BR - L | Viscous heater ON signal | Ignition switch START Heater switch ON Temperature control knob: Max HOT Blower switch ON Coolant temperature 65 °C (149°F) or more | Above 7.8 V |
| AC2 (V6-5) - GND (V6-15) | BR - L | Viscous heater ON signal | Ignition switch START Heater switch OFF Temperature control knob: except Max HOT Blower switch ON Coolant temperature 65 °C (149°F) or more | Below 1 V |
| BLW (V6-2) - GND (V6-15) | R-L - L | Max HOT switch signal | Ignition switch ON Temperature control knob: Max HOT Blower switch ON | 10 to 14 V |
| BLW (V6-2) - GND (V6-15) | R-L - L | Max HOT switch signal | Ignition switch ON Temperature control knob: except Max HOT Blower switch ON | Below 1 V |
| SWVC (V6-13) - GND (V6-15) | L-O - L | Heater switch input signal | Ignition switch START Heater switch ON Temperature control knob: Max HOT Blower switch ON Coolant temperature 65 °C (149°F) or more | Below 1 V |
| SWVC (V6-13) - GND (V6-15) | L-O - L | Heater switch input signal | Ignition switch START Heater switch OFF Temperature control knob: except Max HOT Blower switch ON Coolant temperature 65 °C (149°F) or more | 10 to 14 V |
| SWIN (V6-8) - ND (V6-15) | P - L | Heater switch indicator light signal | Ignition switch START Heater switch ON Temperature control knob: Max HOT Blower switch ON Coolant temperature 65 °C (149°F) or more | 10 to 14 V |
| SWIN (V6-8) - GND | P - L | Heater switch indicator light signal | Ignition switch START Heater switch OFF Temperature control knob: except Max HOT Blower switch ON Coolant temperature 65 °C (149°F) or more | Below 1 V |
| TW (V6-4) - GND (V6-15) | P - L | Water temperature signal | Ignition switch START | Pulse generation |
| TACO (V6-11) - GND (V6-15) | B-W - L | Tachometer signal | Engine running | Pulse generation (see waveform 1) |
| ALT (V6-14) - GND (V6-15) | G - L | Generator | Engine running | Pulse generation |
| PCT1 (V6-6) - GND (V6-15) | R-W - L | PTC heater relay signal | Ignition switch START Heater switch ON Temperature control knob: Max HOT Blower switch ON Coolant temperature: 65°C (149°F) or lower | 10 to 14 V |
| PTC1 (V6-6) - GND (V6-15) | R-W - L | PTC heater relay signal | Ignition switch START Heater switch OFF Temperature control knob: except Max HOT Blower switch OFF Coolant temperature: 65°C (149°F) or lower | Below 1 V |
| PTC2 (V6-7) GND (V6-15) | GR - L | PTC heater relay signal | Ignition switch START Heater switch ON Temperature control knob: Max HOT Blower switch ON Coolant temperature: 65°C (149°F) or lower | 10 to 14 V |
| PTC2 (V6-7) - GND (V6-15) | GR - L | PTC heater relay signal | Ignition switch START Heater switch OFF Temperature control knob: except Max HOT Blower switch OFF Coolant temperature: 65°C (149°F) or lower | Below 1 V |
Inspect using an oscilloscope.
![]() |
Waveform 1 (Reference)
| Item | Content |
| Symbols (Terminal No.) | TACO (V6-11) - GND (V6-15) |
| Tool Setting | 5 V/DIV., 20 msec./DIV. |
| Condition | Engine idling |
| CHECK ECM |

Measure the voltage of the connectors.
2KD-FTV
| Symbols (Terminal NO.) | Wiring color | Terminal Description | Condition | Specified Condition |
| ACT (E6-19) - E01 (E8-7) | R-L - W-B | Magnet on permit signal | Ignition switch START Heater switch OFF Blower switch ON A/C switch OFF | Below 1 V |
| ACT (E6-19) - E01 (E8-7) | R-L - W-B | Magnet on permit signal | Ignition switch START Heater switch ON Blower switch ON A/C switch ON | 10 to 14 V |
| AC1 (E6-18) - E01 (E8-7) | Y - W-B | Idle-up request signal | Ignition switch START A/C magnet clutch is engaged | Below 1 V |
| AC1 (E6-18) - E01 (E8-7) | Y - W-B | Idle-up request signal | Ignition switch START A/C magnet clutch is not engaged | 10 to 14 V |
| HSW (E6-20) - E01 (E8-7) | L-W - W-B | Heater switch output signal for idle-up | Ignition switch START Blower switch ON Power heater switch ON Temperature control knob: Max HOT | Below 1 V |
| HSW (E6-20) - E01 (E8-7) | L-W - W-B | Heater switch output signal for idle-up | Ignition switch START Blower switch OFF Power heater switch OFF Temperature control knob: Max HOT | 10 to 14 V |
| THWO (E5-2) - E01 (E8-7) | P -W-B | Ignition switch ON | Ignition switch START | Pulse generation |
| TACH (E5-4) - E01 (E8-7) | B-W - W-B | Tachometer signal | Engine running | Pulse generation (see waveform 1) |
| Symbols (Terminal NO.) | Wiring color | Terminal Description | Condition | Specified Condition |
| ACT (E6-19) - E01 (E8-7) | R-L - W-B*1 V - W-B*2 | Viscous heater permit signal | Ignition switch START Heater switch OFF Blower switch ON Coolant temperature: 65°C (149°F) or lower Temperature control knob: except Max HOT | Below 1 V |
| ACT (E6-19) - E01 (E8-7) | R-L - W-B*1 V - W-B*2 | Viscous heater permit signal | Ignition switch START Heater switch ON Blower switch ON Coolant temperature: 65°C (149°F) or lower Temperature control knob: Max HOT | 10 to 14 V |
| AC1 (E6-18) - E01 (E8-7) | BR - W-B | Viscous heater on signal | Ignition switch START Viscous magnet clutch is engaged | Below 1 V |
| AC1 (E6-18) - E01 (E8-7) | BR - W-B | Viscous heater on signal | Ignition switch START Viscous magnet clutch is not engaged | 10 to 14 V |
| THWO (E5-2) - E01 (E8-7) | P -W-B | Ignition switch ON | Ignition switch START | Pulse generation |
| TACH (E5-4) - E01 (E8-7) | B-W - W-B | Tachometer signal | Engine running | Pulse generation (see waveform 1) |
![]() |
Inspect using an oscilloscope.
Waveform 1 (Reference)
| Item | Content |
| Symbols (Terminal No.) | TACH (E5-4) - E01 (E8-7) |
| Tool Setting | 5 V/DIV., 20 msec./DIV. |
| Condition | Engine idling |