Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › VISCOUS HEATER MAGNET CLUTCH (for Cold Area)

VISCOUS HEATER MAGNET CLUTCH (for Cold Area) > REMOVAL

for Preparation Click here



1. REMOVE NO. 1 ENGINE UNDER COVER SUB-ASSEMBLY


2. REMOVE FAN & GENERATOR V BELT


3. DISCONNECT WATER BY-PASS HOSE


    I034099E02
  1. Using pliers, grip the claws of clip and side the clip and disconnect the water by-pass hose.



4. DISCONNECT HEATER WATER OUTLET HOSE

HINT:
Use the same procedures for the water by-pass hose.



5. REMOVE VISCOUS WITH MAGNET CLUTCH ASSEMBLY


    I034100E02
  1. Disconnect the connector.

  1. Remove the 2 bolts and viscous with magnet clutch heater assembly.