Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 2KD-FTV FUEL

2KD-FTV FUEL > SERVICE DATA



Supply pump (suction control valve)
Resistance
at 20 °C (68 °F)
1.9 to 2.3 Ω
Injector
Resistance
at 20 °C (68 °F)
0.42 to 0.52 Ω
Common rail
fuel pressure sensor
Resistance
2-3
at 25 °C (77 °F)
16.4 kΩ or less
5-4
at 25 °C (77 °F)
16.4 kΩ or less
1-2
at 25 °C (77 °F)
3 kΩ or less
6-5
at 25 °C (77 °F)
3 kΩ or less
pressure discharge valve
Resistance
1-2
at 20 °C (68 °F)
0.85 to 1.05 Ω
Level warning switch
Specified condition
1-2 (ON)
Below 1Ω
1-2 (OFF)
10kΩ or higher
Fuel filter assembly (Warning switch)
Resistance
at 20 °C (68 °F)
Below 1Ω
Fuel temperature sensor
Resistance
at 20 °C (68 °F)
2.32 to 2.59 kΩ
at 80 °C (176 °F)
0.310 to 0.326 kΩ
Supply pump drive shaft pulley
Thrust clearance
0.15 to 0.55 mm (0.0059 to 0.0217 in.)