Home › ENGINE · 1KD-FTV › ENGINE CONTROL SYSTEM › ECD SYSTEM (w/o EGR Cooler)

DTC    P0489    Exhaust Gas Recirculation Control Circuit Low

DTC    P0490    Exhaust Gas Recirculation Control Circuit High

for Preparation Click here


DESCRIPTION

The EGR system recirculates exhaust gases, in order to suit every driving condition. The recirculated gas mingles with intake air, therefore the EGR system can slow combustion speed and keep the combustion temperature down. This helps reduce NOx emission.
In order to increase EGR circulation efficiency, the ECM adjusts the lift amount of the EGR valve and throttle valve angle.

DTC No.
DTC Detection Condition
Trouble Area
P0489
Open or short in E-VRV circuit for 5 seconds or more
(1 trip detection logic)
  1. E-VRV
  2. Open or short in E-VRV circuit
  3. ECM
P0490
Open or short in E-VRV circuit for 5 seconds or more
(1 trip detection logic)
  1. E-VRV
  2. Open or short in E-VRV circuit
  3. ECM

WIRING DIAGRAM


A154731E16


INSPECTION PROCEDURE

NOTICE:
After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).

1.INSPECT E-VRV FOR EGR
  1. Inspect the E-VRV for EGR (Click here).



NG
REPLACE E-VRV FOR EGR (Click here)
OK


2.INSPECT E-VRV FOR EGR (POWER SOURCE VOLTAGE)


    A199385E07
  1. Disconnect the V1 E-VRV for EGR connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage of the wire harness side connector and body ground.

    Standard voltage:
    Tester Connection
    Specified Condition
    V1-1 - Body ground
    11 to 14 V



NG
Go to step 4
OK


3.CHECK HARNESS AND CONNECTOR (E-VRV FOR EGR - ECM)


    A201250E07
  1. Disconnect the V1 E-VRV for EGR connector.

  1. Disconnect the E7 ECM connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    V1-2 - EGR (E7-9)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    V1-2 or EGR (E7-9) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECM (Click here)  

4.CHECK HARNESS AND CONNECTOR (E-VRV FOR EGR - INTEGRATION RELAY)
A201249E08
  1. Remove the integration relay from the engine room junction block .

  1. Disconnect the 1J integration relay connector.

  1. Disconnect the V1 E-VRV for EGR connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    1J-5 - V1-1
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    1J-5 - V1-1
    Below 1 Ω
    1J-5 or V1-1 - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

INSPECT ECM POWER SOURCE CIRCUIT (Click here)