STARTER (for BOSCH Made) > INSPECTION |
| 1. INSPECT STARTER ASSEMBLY |

Perform pull-in test.
Remove the nut, and then disconnect the field coil core from terminal C.
Connect the battery to the magnet starter switch as shown in the illustration. Then check that the clutch pinion gear moves outward.

Perform holding test.
When the battery is connected as above with the clutch pinion gear out, disconnect the negative (-) lead from terminal C. Check that the pinion gear remains out.

Inspect clutch pinion gear return.
Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns inward.

Perform operation test without load.
Connect the field coil lead wire to terminal C with the nut.
Mount the starter in a vise between aluminum plates.
Connect the battery and ammeter to the starter as shown in the illustration.
Check that the starter rotates smoothly and steadily while the pinion gear is moving outward. Then measure the current.

| 2. INSPECT STARTER ARMATURE ASSEMBLY |
![]() |
Measure the resistance.
Measure the resistance between the segments of the commutator.
![]() |
Measure the resistance between a segment of the commutator and armature coil core.
![]() |
Inspect the commutator circle runout.
Place the commutator on V-blocks.
Using a dial indicator, measure the circle runout.
![]() |
Using a vernier caliper, measure the commutator diameter.
![]() |
Using a vernier caliper, measure the undercut depth of the commutator.
| 3. INSPECT STARTER BRUSH HOLDER ASSEMBLY |
![]() |
Using a vernier caliper, measure the brush length.
![]() |
Check the brush holder.
Measure the resistance between the brushes.
| Tester Connection | Specified Condition |
| A - B | 10 kΩ or higher |
| A - C | 10 kΩ or higher |
| A - D | Below 1 Ω |
| B - C | Below 1 Ω |
| B - D | 10 kΩ or higher |
| C - D | 10 kΩ or higher |
| 4. INSPECT STARTER CLUTCH SUB-ASSEMBLY |
![]() |
Check the starter clutch pinion gear.
Rotate the pinion gear clockwise and check that it turns freely. Try to rotate the pinion gear counterclockwise and check that it locks.
If the result is not as specified, replace the starter clutch sub-assembly.
| 5. INSPECT MAGNET STARTER SWITCH ASSEMBLY |
![]() |
Check the plunger.
Install the plunger and spring onto the switch body.
![]() |
Push in the plunger and check that it returns quickly to its original position.
If the result is not as specified, replace the magnet starter switch assemby.
![]() |
Check if the pull-in coil has an open circuit.
Measure the resistance between terminal 50 and terminal C.
![]() |
Check if the hold-in coil has an open circuit.
Measure the resistance between terminal 50 and the switch body.