ECT
Tester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Neutral Position SW Signal
| PNP switch status/ ON or OFF
| - Shift lever in P or N: ON
- Shift lever not in P or N: OFF
| When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the PNP switch or shift cable may be incorrect.
|
Shift SW Status (R Range)
| PNP switch status/ ON or OFF
| - Shift lever in R: ON
- Shift lever not in R: OFF
| When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the PNP switch or shift cable may be incorrect.
|
Shift SW Status (2 Range)
| PNP switch status/ ON or OFF
| - Shift lever in 2: ON
- Shift lever not in 2: OFF
| When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the PNP switch or shift cable may be incorrect.
|
Shift SW Status (L Range)
| PNP switch status/ ON or OFF
| - Shift lever in L: ON
- Shift lever not in L: OFF
| When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the PNP switch or shift cable may be incorrect.
|
Shift SW Status (D Range)
| PNP switch status/ ON or OFF
| - Shift lever in D: ON
- Shift lever not in D: OFF
| When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the PNP switch or shift cable may be incorrect.
|
Shift SW Status (3 Range)
| PNP switch status/ ON or OFF
| - Shift lever in 3: ON
- Shift lever not in 3: OFF
| When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the PNP switch or shift cable may be incorrect.
|