VVT SENSOR > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. DRAIN ENGINE COOLANT |
Remove the radiator cap.

Loosen the cylinder block drain cock plug and radiator drain cock plug, and then drain the coolant.
| 3. REMOVE V-BANK COVER |
![]() |
Remove the 2 nuts and V-bank cover.
| 4. REMOVE NO. 2 VENTILATION HOSE |
![]() |
| 5. REMOVE AIR CLEANER ASSEMBLY |
![]() |
Disconnect the vacuum hose.
Disconnect the MAF meter connector.
Remove the 2 wire harness clamps.
![]() |
Loosen the 2 hose clamps.
Remove the 2 bolts and air cleaner.
| 6. REMOVE VVT SENSOR (for Bank 1) |
![]() |
Disconnect the sensor connector.
Remove the bolt and sensor.
| 7. REMOVE VVT SENSOR (for Bank 2) |
![]() |
Disconnect the No. 4 and No. 5 water by-pass hoses.
Disconnect the sensor connector.
![]() |
Remove the bolt and sensor.