Home › BODY › WINDSHIELD / WINDOWGLASS › POWER WINDOW CONTROL SYSTEM (for RHD)

POWER WINDOW CONTROL SYSTEM (for RHD) > Power Windows do not Operate at All

for Preparation Click here


DESCRIPTION

If all of the power windows do not operate, the power window regulator master switch may have no power or may be malfunctioning.

WIRING DIAGRAM


B149735E01


INSPECTION PROCEDURE

1.INSPECT FUSE (ECU-IG & GAUGE)
  1. Remove the ECU-IG & GAUGE fuse from the instrument panel junction block.

  1. Measure the resistance of the fuse.

    Standard resistance:
    Below 1 Ω



NG
REPLACE FUSE
OK


2.INSPECT IG1 RELAY
B112776E05
  1. Remove the IG1 relay from the No. 3 relay block.

  1. Measure the resistance of the relay.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Below 1 Ω
    (when battery voltage is applied to terminals 1 and 2)



NG
REPLACE IG1 RELAY
OK


3.INSPECT IGNITION SWITCH ASSEMBLY
A087913E01
  1. Remove the ignition switch.

  1. Measure the resistance of the switch.

    Standard resistance:
    Tester Connection
    Switch Position
    Specified Condition
    1 (IG1) - 4 (AM1)
    OFF
    10 kΩ or higher
    1 (IG1) - 4 (AM1)
    ON
    Below 1 Ω



NG
REPLACE IGNITION SWITCH ASSEMBLY
OK


4.CHECK WIRE HARNESS (MASTER SWITCH - BATTERY AND BODY GROUND)
B117126E06
  1. Disconnect the P6 master switch connector.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    P6-6 (B) - Body ground
    Ignition switch ON
    10 to 14 V

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Tester Connection
    Specified Condition
    P6-3 (E) - Body ground
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY