DTC P0710 Transmission Fluid Temperature Sensor "A" Circuit |
DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |
| ATF Temperature Sensor State | Detection Condition | Symptom | Recovery Condition |
| Sensor is normal | ATF temperature higher than 130°C (266°F) | Shift point too low | ATF temperature below 125°C (257°F) |
| When conditions (a) and (b) are satisfied: (a) ATF temperature higher than 130°C (266°F) (b) Engine coolant temperature higher than 98°C (208°F) | Lock-up in 4th or 3rd gear* | ATF temperature below 110°C (230°F) and engine coolant temperature below 98°C (208°F) | |
| Sensor is short-circuited | Any conditions | Shift point too low | Symptoms still occur |
| Engine coolant temperature higher than 95°C (203°F) | Lock-up in 4th or 3rd gear* | Symptoms still occur |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0710 | ATF temperature sensor resistance changes from (a) to (b) or from (b) to (a) in less than 0.5 sec., and P0712 and P0713 are not detected (1-trip detection logic): (a) ATF temperature sensor resistance is less than 79 Ω (b) ATF temperature sensor resistance is more than 156 kΩ |
|
| P0712 | ATF temperature sensor resistance is below 79 Ω for 0.5 sec. or more (1-trip detection logic). |
|
| P0713 | When 15 minutes or more have elapsed after the engine is started, ATF temperature sensor resistance is higher than 156 kΩ for 0.5 seconds or more (1-trip detection logic). |
|

| DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List.
According to the display on the tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 3 | ATF temperature sensor value/ Min.: -40°C (-40°F) Max.: 215°C (419°F) |
| If the value is -40°C (-40°F) or 215°C (419°F), the ATF temperature sensor circuit is open or shorted. |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or higher | Short circuit |
| 1.INSPECT ATF TEMPERATURE SENSOR |
![]() |
Disconnect the A3 ATF temperature sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | Always | 79 Ω to 156 kΩ |
| 1 - Body ground | Always | 10 kΩ or higher |
| 2 - Body ground | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 20°C (68°F) | 10.3 to 13.9 kΩ |
| 120°C (248°F) | 0.58 to 0.65 kΩ |
| *a | Component without harness connected (ATF Temperature Sensor) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (ATF TEMPERATURE SENSOR - ECM) |
![]() |
Disconnect the E11 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E11-22 (THOC) - E11-28 (E2) | Always | 79 Ω to 156 kΩ |
| E11-22 (THOC) - Body ground | Always | 10 kΩ or higher |
| E11-28 (E2) - Body ground | Always | 10 kΩ or higher |
| *a | Rear view of wire harness connector (to ECM) |
|
| ||||
| OK | ||
| ||