Home › ENGINE ยท 1KD-FTV › CHARGING › GENERATOR

GENERATOR > REMOVAL

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



2. REMOVE AIR CLEANER ASSEMBLY


A099628E02
  1. Disconnect the MAF meter connector and remove the clamp.

  1. Loosen the hose clamp of the compressor inlet elbow.

  1. Remove the 2 bolts and air cleaner.



3. REMOVE FAN AND GENERATOR V BELT


    G035153E01
  1. Rotate the tensioner pulley clockwise to loosen the belt's tension. Then remove the V belt.



4. REMOVE GENERATOR ASSEMBLY


A125326
  1. Disconnect the terminal cap.

  1. Remove the nut and generator wire.

  1. Disconnect the generator connector.

  1. Remove the 2 bolts and generator.