Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
Cold
1630 to 2740 Ω
1 - 2
Hot
2065 to 3225 Ω
NOTICE:
In the chart above, the terms "cold" and "hot" refer to the temperature of the sensor. "Cold" means approximately -10 to 50°C (14 to 122°F). "Hot" means approximately 50 to 100°C (122 to 212°F).
If the result is not as specified, replace the crankshaft position sensor.