THERMOSTAT > INSPECTION |
| 1. INSPECT THERMOSTAT |
![]() |
Immerse the thermostat in water and then gradually heat the water.
Check the valve opening temperature.
![]() |
Check the valve lift.
| *1 | Valve Lift |
Check that the valve is fully closed when the thermostat is below 77°C (171°F).
If the valve is not fully closed, replace the thermostat.