GENERATOR > INSPECTION |
| 1. INSPECT GENERATOR ROTOR ASSEMBLY |
![]() |
Check the rotor for an open circuit.
Measure the resistance between the slip rings.
![]() |
Check if the rotor is grounded.
Measure the resistance between the slip ring and rotor.
Check that the slip rings are not rough or scored.
If rough or scored, replace the rotor assembly.
![]() |
Using a vernier caliper, measure the slip ring diameter.
| 2. INSPECT GENERATOR STATOR SUB-ASSEMBLY WITH RECTIFIER |

![]() |
Inspect the positive (+) rectifier.
Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.
Reverse the polarity of the tester probes and repeat the step above.
Check that one shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.
If the result is not as specified, replace the generator stator sub-assembly with rectifier.
![]() |
Inspect the negative (-) rectifier.
Using an ohmmeter, connect one tester probe to each negative (-) terminal and the other to each rectifier terminal.
Reverse the polarity of the tester probes and repeat the step above.
Check that one shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.
If the result is not as specified, replace the generator stator sub-assembly with rectifier.
![]() |
Inspect the stator coil for an open circuit.
Measure the resistance between the rectifier terminals.
| 3. INSPECT BRUSH |
![]() |
Using a vernier caliper, measure the exposed brush length.