BRAKE PEDAL (w/o VSC) > INSTALLATION |
| 1. INSTALL BRAKE PEDAL SUPPORT SUB-ASSEMBLY |
![]() |
Install the support with the 4 nuts.
![]() |
for 1KD-FTV, 2KD-FTV and 5L-E with Manual Transmission:
Attach the connector clamp and clamp to the brake pedal support sub-assembly.
![]() |
Install the bolt to the support.
Connect the stop light switch connector to the switch.
| 2. CONNECT BRAKE MASTER CYLINDER PUSH ROD CLEVIS |
![]() |
Apply a light coat of lithium soap base glycol grease to the clevis pin.
Connect the push rod clevis to the brake pedal.
Install the clevis pin and a new clip.
Install the return spring.
| 3. CHECK AND ADJUST BRAKE PEDAL HEIGHT |
![]() |
Check the pedal height.
| Model | Specified Condition |
| for LHD | 152.9 to 162.9 mm (6.020 to 6.413 in.) |
| for RHD (Manual Transmission) | 156.9 to 166.9 mm (6.177 to 6.571 in.) |
| for RHD (Automatic Transmission) | 158.1 to 168.1 mm (6.224 to 6.618 in.) |
Adjust the pedal height.
Disconnect the connector from the stop light switch.
Remove the switch.
Loosen the push rod clevis lock nut.
Adjust the pedal height by turning the push rod.
Tighten the lock nut.
![]() |
Insert the switch into the adjuster until it slightly touches the pedal.
![]() |
Turn the switch a quarter turn clockwise.
Connect the connector to the switch.
Check the switch clearance.
| 4. CHECK BRAKE PEDAL FREE PLAY |
![]() |
Stop the engine. Depress the pedal several times until there is no vacuum in the booster. Then release the pedal.
Depress the pedal until resistance is felt.
Check the pedal's free play by measuring the distance between the position in the previous step and the pedal's released position.
Check the switch clearance.
| 5. CHECK BRAKE PEDAL RESERVE DISTANCE |
![]() |
Release the parking brake lever. Start the engine.
Depress the pedal and check the pedal reserve distance.
Depress the pedal with a force of 490 N (50 kgf, 110 lbf).
Measure the distance between the pedal and dash panel shown in the illustration.
| Model | Specified Condition |
| for LHD | 85.0 mm (3.347 in.) |
| for RHD | 89.0 mm (3.504 in.) |
| 6. INSTALL COMBINATION METER ASSEMBLY |
Install the combination meter (Click here).
| 7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |