CHARGING SYSTEM > Charging Failure |
| 1.CHECK LOCK FUNCTION OF GENERATOR PULLEY WITH CLUTCH |
Start the engine and visually check if the fan of the generator rotor assembly located inside the generator assembly is operating.
|
| ||||
| OK | |
| 2.CHECK GENERATOR PULLEY WITH CLUTCH (UNIT INSPECTION) |
Remove the generator assembly (Click here).
Check the installation condition of the generator pulley cap.
Check for grease leaks (for wet pulley) or particle formation due to friction (for dry pulley).
Check the generator pulley with clutch for misalignment (interference with the generator assembly).
![]() |
Turn the generator pulley with clutch clockwise and counterclockwise by hand and check for noise.
Turn the generator pulley with clutch clockwise and counterclockwise by hand and visually check for runout.
![]() |
Using a screwdriver, hold the fan of the generator rotor assembly located inside the generator assembly in place and check that the generator pulley with clutch locks when turned clockwise and turns freely when turned counterclockwise.
|
| ||||
| OK | ||
| ||