POWER WINDOW MASTER SWITCH (for LHD) > INSPECTION |
| 1. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY |
Measure the resistance of the power switch.

| Tester Connection | Window Lock Switch Condition | Switch Condition | Specified Condition |
| 3 (E) - 9 (DD), 4 (DU) - 6 (B) | Always (ON / OFF) | UP | Below 1 Ω |
| 3 (E) - 4 (DU), 3 (E) - 9 (DD) | Always (ON / OFF) | OFF | Below 1 Ω |
| 3 (E) - 4 (DU), 6 (B) - 9 (DD) | Always (ON / OFF) | DOWN | Below 1 Ω |
| 3 (E) - 4 (DU), 6 (B) - 9 (DD) | Always (ON / OFF) | AUTO DOWN | Below 1 Ω |
| Tester Connection | Window Lock Switch Condition | Switch Condition | Specified Condition |
| 3 (E) - 15 (PD), 6 (B) - 18 (PU) | OFF | UP | Below 1 Ω |
| 3 (E) - 18 (PU), 3 (E) - 15 (PD) | OFF | OFF | Below 1 Ω |
| 3 (E) - 18 (PU), 6 (B) - 15 (PD) | OFF | DOWN | Below 1 Ω |
| 3 (E) - 15 (PD) | ON | UP | 10 kΩ or higher |
| 6 (B) - 18 (PU) | Below 1 Ω | ||
| 18 (PU) - 15 (PD) | ON | OFF | Below 1 Ω |
| 3 (E) - 18 (PU) | ON | DOWN | 10 kΩ or higher |
| 6 (B) - 15 (PD) | Below 1 Ω |
| Tester Connection | Window Lock Switch Condition | Switch Condition | Specified Condition |
| 3 (E) - 13 (RLD), 6 (B) - 12 (RLU) | OFF | UP | Below 1 Ω |
| 3 (E) - 12 (RLU), 3 (E) - 13 (RLD) | OFF | OFF | Below 1 Ω |
| 3 (E) - 12 (RLU), 6 (B) - 13 (RLD) | OFF | DOWN | Below 1 Ω |
| 3 (E) - 13 (RLD) | ON | UP | 10 kΩ or higher |
| 6 (B) - 12 (RLU) | Below 1 Ω | ||
| 12 (RLU) - 13 (RLD) | ON | OFF | Below 1 Ω |
| 3 (E) - 12 (RLU) | ON | DOWN | 10 kΩ or higher |
| 6 (B) - 13 (RLD) | Below 1 Ω |
| Tester Connection | Window Lock Switch Condition | Switch Condition | Specified Condition |
| 3 (E) - 16 (RRD), 6 (B) - 10 (RRU) | OFF | UP | Below 1 Ω |
| 3 (E) - 10 (RRU), 3 (E) - 16 (RRD) | OFF | OFF | Below 1 Ω |
| 3 (E) - 10 (RRU), 6 (B) - 16 (RRD) | OFF | DOWN | Below 1 Ω |
| 3 (E) - 16 (RRD) | ON | UP | 10 kΩ or higher |
| 6 (B) - 10 (RRU) | Below 1 Ω | ||
| 10 (RRU) - 16 (RRD) | ON | OFF | Below 1 Ω |
| 3 (E) - 10 (RRU) | ON | DOWN | 10 kΩ or higher |
| 6 (B) - 16 (RRD) | Below 1 Ω |
![]() |
Apply battery voltage to the master switch and check that the AUTO light illuminates.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 6 (B) Battery negative (-) → Terminal 3 (E) | AUTO light illuminates |