HEATER & AIR CONDITIONING SYSTEM
›
AIR CONDITIONING
›
FRONT EVAPORATOR TEMPERATURE SENSOR
FRONT EVAPORATOR TEMPERATURE SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT EVAPORATOR TEMPERATURE SENSOR
Measure the resistance of the sensor.
resistance:
Tester Connection
Condition
Specified Condition
1 - 2
0°C (32°F)
4.40 to 5.35 kΩ
1 - 2
15°C (59°F)
2.14 to 2.58 kΩ
NOTICE:
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be almost the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see graph).
If the result is not as specified, replace the evaporator temperature sensor.