Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › REAR BLOWER CONTROL SWITCH

REAR BLOWER CONTROL SWITCH > INSPECTION

for Preparation Click here



1. INSPECT COOLER CONTROL SWITCH ASSEMBLY


    E128900E02
  1. Measure the resistance of the control switch.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    5 - 4
    LO
    Below 1 Ω
    5 - 4
    5 - 3
    M1
    Below 1 Ω
    5 - 4
    5 - 2
    M2
    Below 1 Ω
    5 - 4
    5 - 1
    HI
    Below 1 Ω

    1. If the result is not as specified, replace the switch assembly.



2. INSPECT COOLER(REAR) SWITCH


    E117043
  1. Measure the resistance of the cooler switch.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    3 - 4
    ON
    Below 1 Ω
    3 - 4
    OFF
    10 kΩ or higher

  1. Apply battery voltage to the cooler switch connector and check that the indicator lamp illuminates.

    OK:
    Measurement Connection
    Switch Condition
    Specified Condition
    Battery positive (+) → Terminal 6
    Battery negative (-) → Terminal 3
    ON
    Indicator light illuminates

    If the result is not as specified, replace the switch.